background image

microMIND V2 (secure printing and copy accounting / device locking)

2

Introduction

Summary of Contents for microMIND V2

Page 1: ...microMIND V2 Installation Configuration Manual...

Page 2: ......

Page 3: ...elix Schlick 2 2 Thomas Lemmer 02 Oct 2018 Thomas Lemmer 2 3 Sebastian Husnik 21 Aug 2020 Thomas Lemmer Holger Bauszus 2 4 Thomas Lemmer 16 Jun 2022 Holger Bauszus Christoph Laue 2 5 Claudia Kleinekem...

Page 4: ...pdate via USB Stick on page 15 Added FAT32 as supported file system 2 0 Specifications on page 19 Reformatted chapter moved to end of book added disposal note 2 1 microMIND on page 10 Updated paramete...

Page 5: ...ered in the U S and other countries and regions Box is a trademark of Box Inc CANON iR ADV iR imageRUNNER imageRUNNER ADVANCE MEAP iW and Canon product and services names are the trademark or register...

Page 6: ...r indirectly by this document In addition this manual provides links to the sites of affiliated or independent companies and certain other businesses NT ware is not responsible for examining or evalua...

Page 7: ...ungs GmbH Feedback Should you come across any relevant errors or have any suggestions please contact documentation nt ware com or use the Send feedback button of the uniFLOW Online Help Technical Supp...

Page 8: ...cation of a device also invalidates CE FCC and other certifications and will void the warranty Defective Devices Do not use defective devices cables or accessories Defective devices must be disconnect...

Page 9: ...n the English original Some screenshots diagrams and pictures in this document may not be translated and appear in English language only Send Feedback Should you come across any relevant errors or hav...

Page 10: ......

Page 11: ...nfigurable Parameters 7 5 1 1 Code Conversion 8 6 microMIND V2 Website 10 6 1 microMIND 10 6 2 USB Device 11 6 3 Port Configuration 12 6 4 About 13 7 Firmware Update 15 7 1 Firmware Update via USB Sti...

Page 12: ...9 Specifications 20 9 1 Compliance and Disposal Notes 23 9 2 EU Declaration of Conformity 25 9 3 China RoHS 25 10 FAQ 27 Index II Contents...

Page 13: ...to include almost all printers and install them in uniFLOW as a secure printer However an Ethernet TCP IP network connection is required for the microMIND V2 The microMIND V2 has a built in network sw...

Page 14: ...microMIND V2 secure printing and copy accounting device locking 2 Introduction...

Page 15: ...microMIND V2 package includes The microMIND V2 device A patch cable to connect the device to a printer Power supply if no PoE microMIND V2 The microMIND V2 Installation Guide Hook and loop fastener 3...

Page 16: ...e printer s network cable in one of the RJ45 input 3 jacks 4 Attach the MiCard reader to the microMIND V2 s USB port 4 5 Optional in case copy accounting is required on an MFP Attach the microMIND V2...

Page 17: ...tatus will only be displayed if the microMIND V2 is connected to the network and to a uniFLOW server Green flashing fast If a new firmware has been loaded successfully during the boot loader phase the...

Page 18: ...scriptions Green A link to a network is established Green flashing A link to a network is established and data is transmitting Yellow ON The network speed is 100 Mbit s Yellow OFF The network speed is...

Page 19: ...are set to a fixed IP even if its IP does not match the subnet mask IP Address The IP configuration of the microMIND V2 is performed directly via uniFLOW To configure a microMIND V2 IP address do the...

Page 20: ...option is available in the uniFLOW Server Configuration It has been implemented primarily to support a Code Conversion for microMIND However the Code Conversion can be set to a Global Code Conversion...

Page 21: ...command per line A can be used for comments Apply to microMIND only Yes The Code Conversion only takes place for microMINDs No The Code Conversion should take place for all ID devices Example To remo...

Page 22: ...3 Bytes of the device s MAC address Software Version The current firmware version of the microMIND V2 Network Shows the IP address of the microMIND V2 the Subnet Gateway address and whether it is conf...

Page 23: ...IND V2 The uniFLOW Server will always have access to the microMIND V2 independent of the settings here If left blank there is no access limitation HTTP port 80 must not be blocked by a firewall to rea...

Page 24: ...are distributed through the NT ware project team or support Port Configuration The Port Configuration site allows you to change the DIPORT Settings These can be changed by uploading a certain configur...

Page 25: ...About The About site shows legal information 13 microMIND V2 Website 6 4...

Page 26: ...14 microMIND V2 Website...

Page 27: ...stick according to the requirements listed above 1 2 Copy the MMAPP file onto the USB stick 2 3 Detach your microMIND V2 from the power supply If PoE is used detach the network 3 connection 4 Attach...

Page 28: ...oad a new firmware package and update all microMINDs Clicking on Load will upload the selected file Note that this may take a while and will be confirmed with a pop up message Manual firmware update v...

Page 29: ...e following settings are available Interpreter Parameters DEBOUNCE The number of milliseconds after a signal edge has been detected to suspend monitoring Helps to solve double click problems because o...

Page 30: ...ues in the rules and only in the rules not elsewhere can be entered either in decimal e g 17 binary b10001 octal o21 or hexadecimal 0xd1 or D1 format Comments can be started after the clicks value wit...

Page 31: ...0010 1 0 Copy A3 RULE3 3 b1110 b0100 1 0 Copy A4 Color RULE4 4 b1110 b0000 1 0 Copy A4 RULE5 5 b1110 b1110 1 0 Print A3 Color RULE6 6 b1110 b1010 1 0 Print A3 RULE7 7 b1110 b1100 1 0 Print A4 Color RU...

Page 32: ...onnection with USB 1 1 to connect a MiCard or MiCard PLUS since firmware V2 0 5 reader D SUB 15 Digital I O Connector to lock unlock the machine for copy accounting Indicators The microMIND V2 is equi...

Page 33: ...osed rooms Certifications CE FCC RCM UL VCCI Cleaning Clean the device with a slightly dampened cloth that has been well wrung out Turn off the power unplug the device and unplug the USB connector bef...

Page 34: ...microMIND V2 IO Connector 22 Specifications...

Page 35: ...s Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada For models with integrated RFID functionality This device comp...

Page 36: ...ntsorgen ist NT ware bernimmt f r Sie in bereinstimmung mit der oben genannten Richtlinie die fachgerechte Entsorgung ausgedienter NT ware Hardware Adresse zur R ckf hrung Senden Sie das ausgediente G...

Page 37: ...mes and Contents of Hazardous Substances microMIND V2 Product microMIND V2 Parts Hazardous substance Pb Hg Cd Cr6 PBB PBDE Printed Circuit Board Cables Housing SJ T 11364 This table is formulated in a...

Page 38: ...e symbol shown here unless otherwise marked Certain parts may have a different EFUP for example battery modules and so are marked to reflect such The Environment Friendly Use Period is valid only when...

Page 39: ...leaving the Upload Port I O configuration file field empty How do I run a Telnet session with the microMIND V2 To use Telnet you first should ensure that the Telnet Client is installed on your compute...

Page 40: ...new user name ii Repeat user name ii Repeat the entered user name iii New Password iii Enter a new password iv Repeat password iv Repeat the entered password The new user name and the new password are...

Page 41: ...26 Firmware Update 14 Firmware Update via uniFLOW 16 Firmware Update via USB Stick 15 H How to use this Document 8 I Installation 3 Introduction 1 L LED Status 4 Legal and Safety Notices 8 M microMIND...

Page 42: ...NT ware 2009 2022...

Reviews: