S e c t i o n 6 - S p e c i f i c a t i o n s
85
Service Tone
Description
Freq.
Cadence Specification
0s
2s
3s
6s
5s
4s
1s
7s
Hold Tone – Exchange
Line
425Hz
Ring Back – Exchange
line
425Hz
Answer Tone DISA Calls
1600Hz
(brief tone only)
Power up default settings
All extensions can make and receive external calls (call barring class 0)
Alarm contacts are set to Normally Closed, 90-second entry delay, alarm with tone.
Factory default pin code is 7373
V24 output of SMDR is in PC mode
System is in Day Mode
All extension ringing is immediate, no delays
No internal diversions on busy, no answer are set
All extensions can be either DTMF or Pulse Dialling
Intrusion rights not set
No automatic answering features are programmed
All extensions are set to act as single line telephones, with ringing activated
Default ISDN mode is point to multipoint
Internal hold tone used.
Call waiting tone enabled.
Alternative Carrier Selection is disabled.
Exchange line hold timer is 4½ minutes
Exchange line park timer is 3 minutes
Exchange line call camp timer is 1 minute
Attendant/door phone ring timer is 30 seconds
Extension ring timer is 1½ minutes
Blind transfer timer is 1 minute
Call back extension timer is 30 seconds