Installation

Mounting

 Installation

• A fixed electrical installation must be done by an authorized electrician.

• Maximum five units may be connected in a fixed electrical installation.

• The unit shall be placed in a dry environment with a temperature range from +5° C to + 40° C

(41° F to 104° F).

• The unit shall be mounted to a vertical wall.

• The unit shall be mounted to concrete or plaster walls only.

• Avoid mounting the unit in a sunlit place. This can affect the charging capacity.

Delivery Includes

• Battery Pack Charger

• Power cord including IEC C14 connector (male)

• Inlet accessory kit, including cable support holders and screws
A suitable extension cord is needed to connect a single unit to a wall outlet, unless the C14 con-

nector is replaced (by an electrician). The following item can be ordered from Siemens Enter-

prise Communications GmbH & Co. KG:

Item

Item Number

EU cord

L30280-Z600-F105

UK cord

L30280-Z600-F102

SWZ cord

L30280-Z600-F103

US cord

L30280-Z600-F101

Required Tools etc.

• Screwdrivers

• Cutting pliers

• Multimeter

• Screws and wall plugs for wall mounting.
Make sure the screws and wall plugs have the correct length for the type of wall used.

Wall material

Plug length

Screw diameter

Single plasterboard

Thorsman TP1

3.5 – 5 mm

Double plasterboard

Thorsman TP2

3.5 – 5 mm

Concrete

Thorsman TP2

3.5 – 5 mm

 Mounting

1)

First, make an outline of how the units are to be placed.

2)

If several Battery Pack Chargers (or Charging Racks) are to be mounted close to each oth-

er, mount them so that there is enough space between them to be able to disconnect the bat-

teries or the handsets (vertical distance) and to be able to open the top cover (horizontal dis-

tance).
When you are planning the location of the units, start to mount them in a height that makes it

easy to reach the batteries.

A31003-M2000-J106-01-7631, 25/06/2020

Battery Pack Charger, Installation Guide

7

Summary of Contents for OpenScape WLAN Phone WL4

Page 1: ...Battery Pack Charger OpenScape WLAN Phone WL4 WL4 Plus Installation Guide A31003 M2000 J106 01 7631...

Page 2: ...ify Software and Solutions GmbH Co KG 25 06 2020 All rights reserved Reference No A31003 M2000 J106 01 7631 The information provided in this document contains merely general descriptions or characteri...

Page 3: ...pliance Statements USA Canada only 5 2 Installation 7 2 1 Mounting 7 2 1 1 Remove the Top Cover 8 2 2 Electrical Installation 8 2 2 1 Install Single Unit 9 2 2 2 Install Multiple Units 9 2 3 Charging...

Page 4: ...ts requires a fixed electrical instal lation In the USA and Canada the Battery Pack Charger must only be installed as a single unit Connection of several units is not permitted Safety It is not allowe...

Page 5: ...stances or affect the declaration of substances used in products can be found in the Unify Expert WIKI at http wiki unify com under the section Declarations of Conformity Regulatory Compliance Stateme...

Page 6: ...or modifications to the equipment not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment A31003 M2000 J106 01 7631 25 06 2020 6 Batter...

Page 7: ...ns GmbH Co KG Item Item Number EU cord L30280 Z600 F105 UK cord L30280 Z600 F102 SWZ cord L30280 Z600 F103 US cord L30280 Z600 F101 Required Tools etc Screwdrivers Cutting pliers Multimeter Screws and...

Page 8: ...wall with four screws 400 290 70 5 Figure 2 Mounting dimensions in mm Charging Rack seen from back Remove the Top Cover Remove the top cover by first pressing on the sides of the top cover then liftin...

Page 9: ...to the wall outlet 2 Place a battery in the charging slot 3 A yellow LED indicates that charging starts while a green LED indicates a fully charged bat tery Install Multiple Units Maximum five units m...

Page 10: ...Green Earth Ground Safety Earth Earth Ground Grounding conductor 3 Install Additional Unit 1 Mount the additional unit to the wall 2 Remove the top cover from the previous unit 1 The Old standard was...

Page 11: ...ver 4 Mount the cable support holder at the unused opening on the previous unit The cable sup port holder is provided in the parts bag Figure 7 Remove safety cover 5 Remove the C14 connector from the...

Page 12: ...markings L earth symbol and N Figure 8 Terminal block for power cord 9 Secure the power cord with two screws which are provided in the parts bag Figure 9 Securing the power cord 10 Mount the safety co...

Page 13: ...lly charged bat tery Operation When the charger is connected to external power supply normal operation is done as follows Charging 1 Connect the charger to the AC power supply 2 Place a battery in the...

Page 14: ...shooting Fault Solution Charging does not start Check that the battery is properly inserted in the charger Check the AC power supply connection A31003 M2000 J106 01 7631 25 06 2020 14 Battery Pack Cha...