Administration
Security and Policies
3.13.1.1
Troubleshooting: Lost Password
If the administration and/or user password is lost, and there is no DLS available, new passwords
must be provided. In case of lost administration password, a factory reset is necessary. In case
of lost user password, the administrator may reset the user password. Take the following steps
to initiate a factory reset:
1.
On the phone, press the settings/service key to activate the administration menu (the Menu
key toggles between the user’s configuration menu and the administration menu).
2.
Press the number keys 2-8-9 simultaneously. The factory reset menu opens. If not, the key
combination is deactivated due to security reason.
3.
In the input field, enter the special password for factory reset: "124816".
4.
Confirm by pressing OK.
3.13.2
Certificates
3.13.2.1
Generic
Online Certificate Check
The Online Certificate Status Protocol (OCSP) is used to check if a certificate to be used has
been revoked. This protocol is used to query an Online Certificate Status Responder (OCSR)
at the point when the certificate is being validated. The address of an OCSR can be configured
on the phone and can also be obtained from the certificate to be checked (which will have the
priority).
When
OCSP check
is activated, the configured OCSR is requested to check if the certificate
has been revoked.
OCSR 1 address
specifies the IP address (or FQDN) of a primary OCSP responder.
OCSR 2 address
specifies the IP address (or FQDN) of a secondary OCSP responder.
Administration via WBM
Security and Policies > Certificates > Generic
Generic
OCSP check
OCSR 1 address
OCSR 2 address
Submit