referenz.fm
A31003-C1000-M102-5-76A9, 09/2017
OpenScape Desk Phone CP200/CP205/CP400/CP600 HFA, Administration Manual
177
Technical Reference
Troubleshooting: Error Codes
5.2
Troubleshooting: Error Codes
For a set of error cases, specific error codes are defined. These error codes are shown in brack-
ets on the display, following a general error note. Example: „No Telephony possible (LP1)“.
http://wiki.unify.com/wiki/_SIP_FAQ#Error_codes
Problem
Description
Error code
Network Problem
No network connection
LI1
Not Initialised
Waiting for data
I1
Unable to use LAN
802.1x error
LX1
Unable to use LAN
Physical connection missing
LP1
Unable to Register
Server timeout
RT2
Unable to Register
Server failed
RF2
Unable to Register
Authentication failed
RA2
Unable to Register
No number configured
RN2
Unable to Register
No server configured
RS2
Unable to Register
No registrar configured
RG2
Unable to Register
No DNS domain configured
RD2
Unable to Register
Rejected by server
RR2
Unable to Register
No phone IP address set
RI2
Survivability
Backup route active
B8
Survivability
Backup not configured
RS8
Survivability
Backup timeout
RT8
Survivability
Backup authentication failed
RA8
Cloud-Deployment
abandoned by user
Cloud-Deployment abandoned by user
Occurs when the pin prompt is dismissed
AU
Tabelle 5-1
Troubleshooting Error Codes
>
A special “fast-busy” tone (also called congestion tone) is played if a temporary net-
work problem causes a user-initiated call action to fail. Typical call actions: making
an outgoing call; picking up a call from Manual Hold; or Group pickup. Phone users
and mobile users logged on to the phone. The special tone is triggered if one of the
following SIP response codes is received from the server:
606, 408, or 503.