C.I.B. UNIGAS - M03957CI
35
Oil Flow Rate Settings by means of Berger STM30../Siemens SQM40.. actuator
1
Once the air and gas flow rates are adjusted, turn the burner off, switch the
CM
switch to the heavy oil operation (OIL, on the bur-
ner control panel (see page 39).
2
with the electrical panel open, prime the oil pump acting directly on the related
CP
contactor (see next picture): check the pump
motor rotation and keep pressing for some seconds until the oil circuit is charged;
3
bleed the air from the
M
pressure gauge port (Fig. 37) by loosing the cap without removing it, then release the contactor.
Fig. 37
4
Before starting the burner up, drive the high flame actuator microswitch matching the low flame one (in order to let the burner ope-
rates at the lowest output) to achieve safely the high flame stage .
5
record the high flame value set during the gas operation adjustments (see previous paragraphs);
6
start the burner up by means of the thermostat series and wait until the pre-purge time comes to an end and that the bruner starts
up;
7
drive the burner to high flame stage, by means fo the thermostat
TAB
(high/low flame thermostat - see Wiring diagrams), as far as
fully-modulating burners, see related paragraph.drive the burner to high flame stage, by means fo the thermostat
TAB
, as for fully-
modulating burners, see next paragraphs.
8
Then move progressively the microswitch to higher values until it reaches the high flame position; always check the combustion
values and eventually adjusting the oil pressure (see next step).
9
the nozzle suplly pressureis already factory-set and must not be changed. Only if necessary, adjust the supply pressure as follows
(see related paragraph); insert a pressure gauge into the port shown on Fig. 38 and act on on the pump adjusting screw
VR
(see
Suntec AJ6
Suntec E7
Suntec TA.
Berger STM30
Siemens SQM40
Actuator cams
I
High flame
II
Stand-by and Ignition
III
Low flame - gas
IV
Low flame - oil (SQM40..)
V
Low flame - oil (STM30..)
CP
M
VR
VR
M
VR
M
MAN-AUTO
mensions
Dimensions in
SQM4...
I
III
II
IV
V
VI
VI
V
IV
II
III
I
MAN-AUTO
Summary of Contents for HP60
Page 9: ...C I B UNIGAS M03957CI 9 Overall dimensions mm Boiler recommended drilling template ...
Page 49: ...C I B UNIGAS M03957CI 49 ...
Page 51: ...C I B UNIGAS M03957CI 51 WIRING DIAGRAM Cod 05 680 Progressive burners ...
Page 52: ...C I B UNIGAS M03957CI 52 WIRING DIAGRAM Cod 05 681 Fully modulating burners ...
Page 54: ......
Page 55: ......
Page 56: ......