C.I.B. UNIGAS - M039119CE
8
Specifications
* NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box
immediately starts up, automatically.
BURNERS
NG550
M-.TN..0.25
NG550
M-.TN..0.32
NG550
M-.TN..0.40
NG550
M-.TN..0.50
LG550
L-.TN..0.25
LG550
L-.TN..0.32
LG550
L-.TN..0.40
LG550
L-.TN...0.50
Output
min. - max kW
245 - 570
Fuel
Natural gas
L.P.G.
Gas category
(see next paragraph)
I
3B/P
Gas rate
min.- max Stm
3
/h
26 - 60
9.4 - 22
Gas pressure
min. - max. mbar
(see Note 2)
Power supply
230V - 50Hz
Total power consumption
kW
0.92
Electric motor)
kW
0.62
Protection
IP40
Approx. weight
kg
55
Valves size / Gas connection
1”
/ Rp 1
1”
1/4
/Rp 1
1/4
1”
1/2
/Rp 1
1/2
2”/ Rp 2
1”
/ Rp 1
1”
1/4
/Rp 1
1/4
1”
1/2
/Rp 1
1/2
2”/ Rp 2
Operation
Single stage
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Internittent
BURNERS
NG550
M-.xx..0.25
NG550
M-.xx...0.32
NG550
M-.xx...0.40
NG550
M-.xx...0.50
LG550
L-.xx..0.25
LG550
L-.xx...0.32
LG550
L-.xx...0.40
LG550
L-.xx...0.50
Output
min. - max kW
160 - 570
Fuel
Natural gas
L.P.G.
Gas category
(see next paragraph)
I
3B/P
Gas rate
min.- max Stm
3
/h
17 - 60
6.2 - 22
Gas pressure
min. - max. mbar
(see Note 2)
Power supply
230V - 50Hz
Total power consumption
kW
0.92
Electric motor
kW
0.62
Protection
IP40
Approx. weight
kg
55
Valves size / Gas connection
1”
/ Rp 1
1”
1/4
/Rp 1
1/4
1”
1/2
/ Rp 1
1/2
2” / Rp 2
1”
/ Rp 1
1”
1/4
/ Rp 1
1/4
1”
1/2
/ Rp 1
1/2
2” / Rp 2
Operation
Double stage - Progressive - Fully-modulating
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Internittent
Note1:
All gas flow rates are referred to Stm
3
/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
(nett calorific value
H
i
=
34.02 MJ/Stm
3
); for L.P.G. (nett calorific value
H
i
=
93.5 MJ/Stm
3
)
Note2:
Maximum gas pressure = 360mbar (with
Dungs MBDLE valves)
Minimum gas pressure = see gas curves.