ADJUSTING AIR AND GAS FLOW RATES
Gas Filter
The gas filters remove the dust particles that are present in the gas, and prevent the elements at risk (e.g.: burner valves, counters and
regulators) from becoming rapidly blocked. The filter is normally installed upstream from all the control and on-off devices.
Adjusting the injector gas flow rate: Brahma EG12*R valve and pressure governor
To change the injector gas valve flow rate, proceed as follows:
1
remove the protection on the bottom of the valve, moving it counterclockwise (see next picture);
2
rotate clockwise the nut 1 as shown, to close the valve; counterclockwise to open the valve.
To perform a finest adjustment, act directly on the pressure governor as follows (see next picture):
3
remove the cap
T
: to increase theoutlet gas pressure, use a screwdriver on the screw
TR
as shown in the picture below. Screw to
increase the pressure, unscrew to decrease; once the regulation is performed, replace cap
T
.
Fig. 20
Keys
1
Gas filter
2
Gas proving system
3
Gas valves
4
Adjusting cam
5
Actuator
VPS504 Gas proving system
The VPS504 check the operation of the seal of the gas shut
off valves. This check is carried out as soon as the boiler
thermostat gives a start signal to the burner, creating, by
means of the diaphragm pump inside it, a pressure in the
test space of 20 mbar higher than the supply pressure.
When wishing to monitor the test, install a pressure gauge
ranged to that of the pressure supply point PA.
If the test cycle is satisfactory, after a few seconds the con-
sent light LC (yellow) comes on. In the opposite case the
lockout light LB (red) comes on.
To restart it is necessary to reset the appliance by pressing
the illuminated pushbutton LB.
Fig. 21
3
4
5
1
2
LC
LB
PA
1
T
TR
Brahma gas valve EGR*12
Pressure stabiliser
Summary of Contents for KTP1030
Page 25: ...C I B UNIGAS M039207CB 25 Fig 17 Hydraulic diagram 3ID0014 Two or more burners configuration...
Page 46: ...C I B UNIGAS M039207CB 46...
Page 47: ...C I B UNIGAS M039207CB 47...
Page 48: ...C I B UNIGAS M039207CB 48...
Page 49: ...C I B UNIGAS M039207CB 49...
Page 50: ...C I B UNIGAS M039207CB 50 Pumping Unit Electric Wiring Diagrams...
Page 51: ...C I B UNIGAS M039207CB 51...
Page 52: ...C I B UNIGAS M039207CB 52...
Page 55: ...C I B UNIGAS M039207CB 55...
Page 59: ......
Page 74: ......
Page 83: ......
Page 84: ......
Page 85: ...RWF50 2x RWF50 3x User manual M12922CB Rel 1 0 07 2012...
Page 100: ...16 Note Specifications and data subject to change Errors and omissions excepted...
Page 101: ...KM3 Modulator USER MANUAL M12927CA Rel 1 0 10 2020...
Page 102: ...M12927CA MOUNTING 2...
Page 118: ...1 RWF55 5X RWF55 6X User manual M12926CA Rel 0 1 10 2015...
Page 119: ...2 DEVICE INSTALLATION Fixing system Drilling dimensions...
Page 140: ......
Page 141: ...23 Note Specifications and data subject to change Errors and omissions excepted...