PART III: OPERATION
28
ADJUSTMENTS FOR GAS OPERATION
Adjusting the gas gun
The gas lances are already factory-set at standard position. Only when necessary, change the position following the next procedure:
to move the lance back or forth, loosen the screws
V
, on each lance
to rotate the lance, close the gas manual valve
M
on the lance, loosen the four screws
R
and
V
screws, without removing them;
then rotate the lance in order to change the combustion according to the combustion resulted values.
after the adjustment, remember to fasten all the screws
Attention!
if it is necessary to change the gun position, repeat the air and gas adjustments described above.