Configuration
18.
Advanced Controls
The
Advanced
section contains controls for advanced features of the UFG-05 unit. The
user might need the functions after the installation of the unit but not during the normal
operation. Please use the features in this section with care. When done improperly, they
may impair the correct operation of the UFG-05 unit.
Check firmware
You can check the firmware version loaded into the non-volatile memory of the unit by
clicking
Check Firmware
button. The firmware version must match to the driver
version used. Firmware Update process is described in the
Installation
section earlier in
this manual.
Reset
Repair
Resets the UFG-05 unit. Not needed in normal operation.
A/D Converter Calibration
The A/D converter of the Analog input can be calibrated by using the
Calib ADC
button. The calibration is done to adjust the variations of the integrated circuits. The
A/D converter calibration is done during manufacturing of the UFG-05 unit and the user
does not need normally to use this button.
In order to perform the calibration properly, the set-up needs to fulfill the following
requirements:
The test image source has to be calibrated
The test image must contain large fully white and fully black areas.
The test image must contain smooth horizontal transitions.
You have to use a timing that is well detected and adjusted before color calibration
You have to use RGB
Sub-Type
even if YPbPr will be used later
Note
A/D converter calibration is done during manufacturing and the user does not need to
perform it with his video sources.
If one reason or other you believe that the A/D converter calibration is not correctly set
and if a proper test image source is not available, please use the
Reset ADC
button. It
will reset the calibration data to default values. The result will provide acceptable
captured images but the variations in the integrated circuits will not be compensated.