background image

unigreen  

19

5.3.3 RV BOOM FOR GDC

This boom has lateral diffusers (variable and moveable) and two top
arms with hydraulic or manual adjustment, so the jets can be directed
onto the vegetation to be treated.
In the bottom part there are two adjustable, telescopic distributors for
GDC treatment.
The height of the structure can be adjusted by hand for different types
of vegetation.
The RV-GDC accessory is used with XP fans.

5.4

HYDRAULICS

The RV, VL, VLX, FXF and FXL model distributor accessories have
hydraulics that can be controlled by the operator directly from the seat in the
cab.
Check that no one and nothing is in the area where the booms will open;
particular attention should be paid to the presence of any electric power
lines.

The hydraulic plant can be fed from the hydraulic pump of the tractor.
The hydraulics can be controlled using the lever of the tractor (RV and VL) or
a hydraulic distributor with mechanical or electro-hydraulic command with
switches in the cabin (VLX, FXF and FXL).
- All of the controls on both versions are sustained action controls and each
lever or switch has a pictogram of the relevant operation it controls.

WARNING: with hydraulic booms, don’t stand in the range of action of the
machine.

Pay attention to the integrity and efficiency of the hydraulic components and
in particular to the pipes to prevent the risk of bursting.
Do a full check on the pipes and components at least once a year, we
recommend replacing hydraulic pipes every 3-4 years.

5.4.1 OIL FEED FROM TRACTOR

(for hydraulic systems)
Connect the delivery and discharge quick-fit coupling to the respective
connections, respecting the direction of flow.
The distributor inlet pipe is connected to the aluminium flow separator valve
next to the distributor.
The flow separator must be adjusted correctly so it sends less than 4-5 L/1°
to the distributor.
To prevent the cylinders moving at a dangerous speed, adjust the relevant
chokes near the cylinders. If the registration ringnuts aren’t visible then fixed
chokes are fitted. The chokes are fitted on the discharge line of the
movement to slow.
Any impurities in the oil could block the chokes and as a consequence block
the cylinder; remove the dirt if necessary. The maximum pressure valves of
the distributors are regulated to a pressure of around 150 bar.
To prevent the excessive heating of the oil we recommend supplying the
distributor of the sprayer only when the cylinders are being used.
We recommend having qualified personnel do any adjustments.
Pay attention to the integrity and efficiency of the hydraulic components and
in particular to the pipes to prevent the risk of bursting.
Do a full check on the pipes and components at least once a year, we
recommend replacing hydraulic pipes every 3-4 years.

RV per GDC

Summary of Contents for Minibar

Page 1: ...04 2010 USE AND MAINTENANCE MANUAL MISTBLOWERS AIRDROP MFC MOUNTED MISTBLOWERS serie AIRDROP P ELETTRA P MFC P Ventagli Minibar Super Spalliera RV GDC Read this manual carefully before use GB...

Page 2: ...ACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4 8 1 COMPONENTS OF TH...

Page 3: ...8 7 1 MATERIALS FOR DEMOLITION 24 8 7 2 INDICATIONS FOR A SUITABLE TREATMENT OF WASTE 24 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 24 TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI FANS VR CANOP...

Page 4: ...work speed over that indicated in the spraying tables in the handbook or too high for the conditions of the terrain use of herbicide booms without an auto levelling system or with the auto levelling s...

Page 5: ...h the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous pictograms 20 19 22 21 2 1 6 3 4 5...

Page 6: ...se only after having carefully read the instructions on the container 2 3 1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accidents Keep the machine in a su...

Page 7: ...ese machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed mistblowers are not specifically designed for road use Nevertheless many models are also available in...

Page 8: ...omponents for hydraulic and pneumatic transmissions Hydraulics UNI EN ISO 4254 1 June 2006 Agricultural machines Safety Part 1 General requisites ISO 11684 1995 Pictograms general principles 4 INSTRUC...

Page 9: ...fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the lifting g...

Page 10: ...Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the third point tie...

Page 11: ...the pump FIG 7 NEVER USE THE CARDAN TRANSMISSION IF THE FOLLOWING PROTECTIVE COVERS ARE MISSING TRACTOR POWER TAKEOFF PROTECTIVE COVER CARDAN SHAFT PROTECTIVE COVER FIXED PROTECTIVE COVER ON THE PUMP...

Page 12: ...ion regulator G D auxiliary tap can be used for various accessories it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically...

Page 13: ...t the corresponding compensator G until you return to the pressure set previously displayed on the manometer open and close the tap of section C and check that the pressure remains constant repeat the...

Page 14: ...and after filling stop the pump and put the lever of deviator D back in the working position disconnect pipe T from deviator D b FILLING WITH THE SUCTION FILTER Fig 3 Fig 11 If the 3 way deviator isn...

Page 15: ...llow for using chemical products are indicated in paragraph 2 2 1 4 12 2PREMIXER ON COVER OPTIONAL Open the cover and pour all of the chemical powder into the filter close the cover and open the suppl...

Page 16: ...the power takeoff b Check you have filled the circuit washer tank C c Make sure the main control of the pressure regulator is OFF and that all the boom sectors are closed d Turn suction deviator A to...

Page 17: ...to engage the fan rotor gradually This prevents jerky starts due to the inertia of the fan rotor which can have a negative effect on the transmission For the centrifugal clutch to work properly the s...

Page 18: ...er versions moving the left hand distributor to the right hand and vice a versa the same inversion must be performed for the two distributor taps 1 2 3 4 For particularly high espaliers an upper doubl...

Page 19: ...components and in particular to the pipes to prevent the risk of bursting Do a full check on the pipes and components at least once a year we recommend replacing hydraulic pipes every 3 4 years 5 4 1...

Page 20: ...means a big advantage in terms of uniformity and homogeneity of the jet 6 3 MIXTURE CONCENTRATION As you may know the pneumatic equipment are used for more or less concentrated treatments To prepare t...

Page 21: ...ce 3 5 m volume in l ha 600 x 5 6 177 8 l ha 3 5 x 5 4 6 4 1 BATCHING TAPS SEE PICTURE 20 On the equipment VENTAGLI FANS there are two batching taps which can be used to quickly change the flow rate t...

Page 22: ...e is controlled by opening lever A which depending on how much it s pressed produces a conical spray or direct jet The standard nozzle is 1 5 The mitra spray gun can produce a direct jet or a conical...

Page 23: ...lly in the first period of use We recommend replacing the oil after the first 50 working hours and then subsequently every 500 hours The quantity of oil needed is indicated on the sticker near the mul...

Page 24: ...TABLE TREATMENT OF WASTE The Correct management of special waste envisages stocking in suitable places avoiding mixing dangerous waste with the non dangerous ensuring that authorised carriers and rece...

Page 25: ...137 154 173 192 233 263 281 324 365 370 425 477 472 535 8 112 120 135 152 168 204 230 246 283 319 324 372 418 413 468 2 5 m 4 187 200 225 253 280 340 384 410 472 532 540 620 696 688 780 5 150 160 180...

Page 26: ...5 150 160 189 216 253 280 302 346 384 6 80 91 96 125 133 157 180 211 233 252 288 320 3 7 69 78 82 107 114 135 154 181 200 216 247 274 8 60 68 72 94 100 118 135 158 175 189 216 240 3 m Litri min 2 40 2...

Page 27: ...TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 0578F Velocit Km h speed Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Page 28: ...17 3 19 2 20 1 21 5 TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 000F Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Page 29: ...1 5 nozzle DIAMETER NOZZLE 1 0 1 2 1 5 1 75 2 0 2 2 2 5 PRESSURE BAR JET CAPACITY Lt min 5 cone 1 16 1 40 1 90 2 25 2 65 2 90 3 50 direct jet 1 40 1 70 2 50 3 95 4 7 6 00 7 70 8 cone 1 40 1 80 2 60 2...

Page 30: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 31: ...1 X X X X APS 96 PRESSURE GCP 2 ELECTRIC X X X X REGULATOR GCP 2 ELECTRIC PRES X X X X NOZZLES MFC X X X X DISTRIBUTOR 2 VENTAGLI X X X X ACCESSORIES MINIBAR X X X X SUPER SPALLIERA X X X X RV X X X R...

Page 32: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Reviews: