22
unigreen
In these conditions the two regulators must furnish a liquid flow equal to the half
of the one readable from the table.
In this way is possible to verify if each regulator furnish the right flow of liquid; if
this does not happen , it is sufficient to screw or unscrew slightly the regulator,
until to obtain the requested flow.
6.4.2 CALIBRATED PLATES CP
In the accessories provided with an anti-dripping valve on each sprayer, on the
valve output there is a calibration plate which guarantees an homogeneous
distribution among the various sprayers.
According to the spraying table to be carried out, it is necessary to install the
plate indicated in the table.
NOTE
: The plate must be mounted with the side bearing the initials towards the
liquid output (picture 21).
The values indicated on the tables are approximate; according to the mixture
concentration, spraying values can be slightly different. These differences can
be easily corrected by acting on the working pressure. Increasing pressure
means increasing spraying and vice versa.
7
HAND LANCES
When using hand lances bear in mind the following notes:
=
Don’t direct the jet of liquid towards electric power lines or zones where
there is electrical current, houses or where people might pass.
= Don’t point the jet at people or animals.
The jet can cause serious injuries simply due to the mechanical force of the
liquid under pressure.
=
Never block the spraying lever of the lance in an open position because if
the lance falls it will be uncontrollable.
=
At the end of work after you have stopped the pump, make sure that any
residual pressure in the pipes under pressure has been drained to avoid
unexpected jets when putting the lance away. There are various types of
lances; with a lever, mitra spray gun and pistol grip.
For further information please refer to the handbook in the package.
The lever lance is controlled by opening lever A which, depending on how much
it’s pressed, produces a conical spray or direct jet. The standard nozzle is Ø 1.5
The mitra spray gun can produce a direct jet or a conical spray and the type of
spray is selected by pushing lever B forwards or backwards. Use lever C to
open the jet. The standard nozzle is Ø 2.5
Replacement nozzles are available for all of the lances and the capacities are
indicated in the tables TAB.4 and TAB.5 ( page 29).
8
MAINTENANCE
All of the maintenance operations and repairs must be carried out with the
machine and cardan shaft stopped and the tank and circuit clean of any
residues of chemical products.
The maintenance of the mistblower is essential for maintaining a high level of
safety. Also consult the single handbooks of the main components of the
mistblower.
WARNING: the indications to follow for using chemical products are indicated in
paragraph 2.2.1.
8.1
PROGRAMMED MAINTENANCE
(TAB. N° 7, page 30)
We recommend using a table of programmed maintenance to follow in time to
keep the mistblower in an efficient working condition.
For major and important maintenance jobs we recommend using the normal
UNIGREEN assistance service available from your reseller, (if necessary)
replacing parts using original spare parts only.
8.2
ROUTINE MAINTENANCE
=
After every treatment wash the inside of the tank and the entire circuit as
indicated in paragraph 4.13
=
Periodically check that the suction and delivery filters are clean
=
Check the oil level in the volumetric compensator of the pump
=
The use of chemical products that are particularly damaging for a nitrile
rubber mix can cause the diaphragm to break before time.
In these conditions check the state of the components more often. There are
diaphragms made of special materials (viton and desmopan) that are available
on request.
=
When doing treatments with copper hydroxide you should take great care
to thoroughly clean the system, washing it after each treatment because
hydroxides attack parts that aren’t painted or protected by hot galvanising.
C
B
A
FIG. 22