TABLES FOR CALIBRATING ATOMISERS

TABLES FOR CALIBRATING ATOMISERS  Ø800

N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width
indicated in the table and divide it by the new width (see chapter 6.3, page 20).

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø800 14 getti

Lt./ha spreading rate tab le for Blower Ø800 14 NOZZLES

Piastrina ceramica Ø1,0

Piastrina ceramica Ø1,2

Larghezza di lavoro

PRESSIONE bar

10

15

20

25

30

40

50

10

15

20

25

30

40

50

working width

3,5

1127 1290 1470 1633 1774 2023 2220 1517 1860 2130 2370 2610 3000 3300

4

986 1129 1286 1429 1553 1770 1943 1328 1628 1864 2074 2284 2625 2888

5

789 903 1029 1143 1242 1416 1554 1062 1302 1491 1659 1827 2100 2310

4

6

658 753 858 953 1035 1180 1295 885 1085 1243 1383 1523 1750 1925

7

564 645 735 816 887 1011 1110 759 930 1065 1185 1305 1500 1650

4

3,5

902 1032 1176 1306 1419 1618 1776 1214 1488 1704 1896 2088 2400 2640

4

789 903 1029 1143 1242 1416 1554 1062 1302 1491 1659 1827 2100 2310

5

631 722 823 914 994 1133 1243 850 1042 1193 1327 1462 1680 1848

5

6

526 602 686 762 828 944 1036 708 868 994 1106 1218 1400 1540

7

451 516 588 653 710 809 888 607 744 852 948 1044 1200 1320

5 m.

3,5

751 860 980 1089 1183 1349 1480 1011 1240 1420 1580 1740 2000 2200

4

658 753 858 953 1035 1180 1295 885 1085 1243 1383 1523 1750 1925

5

526 602 686 762 828 944 1036 708 868 994 1106 1218 1400 1540

6

6

438 502 572 635 690 787 863 590 723 828 922 1015 1167 1283

7

376 430 490 544 591 674 740 506 620 710 790 870 1000 1100

6 m.

Litri/min.

26,3 30,1 34,3 38,1 41,4 47,2 51,8 35,4 43,4 49,7 55,3 60,9 70,0 77,0

 Tab. 3215/0000F

ug. sing.

1,88 2,15 2,45 2,72 2,96 3,37 3,70 2,53 3,10 3,55 3,95 4,35 5,00 5,50

Velocità Km/h

s

p

eed

Litri/ha

Litri/ha

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø800 14 getti

Lt./ha spreading rate tab le for Blower Ø800 14NOZZLES

TR80-01 ARANCIO

TR80-015 VERDE

Larghezza di lavoro

PRESSIONE bar

5

7

10

12

15

18

20

5

7

10

12

15

18

20

working width

3,5

304 360 433 467 527 574 604 454 540 643 707 784 866 913

4

266 315 379 409 461 503 529 398 473 563 619 686 758 799

5

213 252 303 327 369 402 423 318 378 450 495 549 606 639

4

6

178 210 253 273 308 335 353 265 315 375 413 458 505 533

7

152 180 216 234 264 287 302 227 270 321 354 392 433 456

4 m.

3,5

243 288 346 374 422 459 483 363 432 514 566 627 693 730

4

213 252 303 327 369 402 423 318 378 450 495 549 606 639

5

170 202 242 262 295 322 338 254 302 360 396 439 485 511

5

6

142 168 202 218 246 268 282 212 252 300 330 366 404 426

7

122 144 173 187 211 230 242 182 216 257 283 314 346 365

5 m.

3,5

203 240 289 311 351 383 403 303 360 429 471 523 577 609

4

178 210 253 273 308 335 353 265 315 375 413 458 505 533

5

142 168 202 218 246 268 282 212 252 300 330 366 404 426

6

6

118 140 168 182 205 223 235 177 210 250 275 305 337 355

7

101 120 144 156 176 191 201 151 180 214 236 261 289 304

6 m.

Litri/min.

7,1

8,4

10,1 10,9 12,3 13,4 14,1 10,6 12,6 15,0 16,5 18,3 20,2 21,3

 Tab. 3215/0000F

ug. sing.

0,51 0,60 0,72 0,78 0,88 0,96 1,01

0,76 0,90 1,07 1,18 1,31 1,44 1,52

Velocità Km/h

s

p

eed

Litri/ha

Litri/ha

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Summary of Contents for Mistblowers AP APC

Page 1: ...USE AND MAINTENANCE MANUAL MISTBLOWERS MOUNTED MISTBLOWERS serie EXPO CLIO KAMBA VENUS DEVIL SIRIO EOLO AP Read this manual carefully before use GB 04 2010 ISO Color code...

Page 2: ...OWED ATOMISERS 9 4 4 TRACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 2 HYDRAULIC CONNECTIONTOTHE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4...

Page 3: ...8 7 2 INDICATIONS FOR A SUITABLETREATMENT OF WASTE 23 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 23 TABLES FOR CALIBRATING ATOMISERS 500 600 25 TABLES FOR CALIBRATING ATOMISERS 600 650 26 TA...

Page 4: ...nd pipes noz zles pressure gauges oil tyres friction material of the clutches Evident cases of negligence include work speed over that indicated in the spraying tables in the handbook or too high for...

Page 5: ...some residual risks associated with the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous...

Page 6: ...roducts license and in any case only after having carefully read the instructions on the container 2 3 1 REGULATIONS FORTHE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accide...

Page 7: ...machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed atomisers are not specifically designed for road use Nevertheless many models are also available in the v...

Page 8: ...ts UNI EN 907 Nov 1998 Agricultural and forestry machinery Sprayers and spreaders of liquid fertilizers Safety UNI EN ISO 13849 1 February 2007 Machinery safety Fundamental concepts general design pri...

Page 9: ...where the fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the...

Page 10: ...ver bumps b Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the thi...

Page 11: ...CTIVE COVER ON THE PUMP SHAFT 4 6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the manufacturer The pump can be identified by the ratings plate o...

Page 12: ...ies it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically compensates variations in speed within the scope of the same ge...

Page 13: ...e the proportional valve may not be able to compensate the speed variations correctly Adjusting the compensated returns close only one tap of section C position OFF adjust the corresponding compensato...

Page 14: ...antipollution hydroejector mounted as standard on some models then you should proceed as follows put roughly 20 30 L of water in the tank and start the pump remove the cap of ejector E and insert fil...

Page 15: ...be filled with clean water and used to rinse the entire circuit including the suction delivery pump pressure regulator jets and nozzles Thanks to the practical rotary nozzle it also rinses the inside...

Page 16: ...tiplier made accessible through the opening on the side in the rear left part of the machine or at a distance on the right side The lever has 2 or 3 positions depending on the number of gears and the...

Page 17: ...only be performed by qualified personnel respecting the position of the single vanes so as not to vary the dynamic balance of the fan unbalanced blowers can cause rapid wear of the multiplier and the...

Page 18: ...e clutch see the previous paragraph This fan rotor can usually produce a delivery which is much higher with a very high speed airflow Fig 25 The cannon fan is mounted on a thrust block that can be adj...

Page 19: ...etation to be treated Poor quality or worn nozzles have a tendency to create unevenly treated strips The nozzles are produced in various sizes to work with a precise pressure range to create certain t...

Page 20: ...44 829 L ha 5 x 6 N B Depending on the season the vegetation may be more or less luxuriant bear this in mind before starting the treatment If the plants don t have much foliage you should diminish the...

Page 21: ...int the jet at people or animals The jet can cause serious injuries simply due to the mechanical force of the liquid under pressure Never block the spraying lever of the lance in an open position beca...

Page 22: ...level If you notice even a partial blockage of a nozzle proceed as follows drain the pressure and stop the machine dismantle the screw or bayonet ringnuts holding the nozzles clean with a small brush...

Page 23: ...DEMOLITION AND DISPOSAL When the sprayer will be put out of service you should wash it with great care to remove any residues of chemical product follow the instructions in point 4 13 of the present...

Page 24: ...ixing G1 4 jets on 1 2 booms 1805 0034F Clamp kit for fixing G1 4 jets on 1 2 booms M8 F thread 1805 0050F TXA80 005 Lilac 3400 0611F ISO nozzle TXA80 067 Olive 3400 0612F ceramic conical TXA80 01 Ora...

Page 25: ...07 346 425 487 542 597 686 754 5 m Litri min 15 0 17 2 19 6 21 8 23 7 27 0 29 6 20 2 24 8 28 4 31 6 34 8 40 0 44 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3 55 3 95 4 35 5...

Page 26: ...20 466 507 578 634 434 531 609 677 746 857 943 5 m Litri min 18 8 21 5 24 5 27 2 29 6 33 7 37 0 25 3 31 0 35 5 39 5 43 5 50 0 55 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3...

Page 27: ...7 387 442 504 559 609 693 761 521 638 730 813 895 1029 1131 5 m Litri min 22 6 25 8 29 4 32 6 35 5 40 4 44 4 30 4 37 2 42 6 47 4 52 2 60 0 66 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Page 28: ...490 544 591 674 740 506 620 710 790 870 1000 1100 6 m Litri min 26 3 30 1 34 3 38 1 41 4 47 2 51 8 35 4 43 4 49 7 55 3 60 9 70 0 77 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 1...

Page 29: ...7 430 491 560 621 677 770 846 579 709 811 903 994 1143 1257 6 m Litri min 30 1 34 4 39 2 43 5 47 4 53 9 59 2 40 5 49 6 56 8 63 2 69 6 80 0 88 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Page 30: ...4 m Litri min 10 6 12 6 15 0 16 5 18 3 20 2 21 3 21 4 25 3 30 4 33 3 37 2 40 7 43 0 Tab 3215 0000F ug sing 0 76 0 9 1 07 1 18 1 31 1 44 1 52 1 53 1 81 2 17 2 38 2 66 2 91 3 07 14 GETTI Velocit Km h s...

Page 31: ...5 205 253 291 323 356 413 468 343 419 485 544 592 683 768 18 6 171 211 242 269 297 344 390 286 349 404 453 493 569 640 7 147 181 208 231 254 295 334 245 299 347 389 423 488 549 18 m Litri min 31 38 4...

Page 32: ...17 579 631 730 910 5 269 328 380 426 463 534 601 292 359 413 463 505 584 728 23 6 224 273 317 355 386 445 501 243 299 344 386 421 487 607 7 192 234 271 304 331 382 429 209 256 295 331 361 417 520 23 m...

Page 33: ...7 387 434 473 548 683 5 201 246 285 319 347 401 451 219 269 310 347 379 438 546 23 6 168 205 237 266 290 334 376 183 224 258 290 316 365 455 7 144 176 203 228 248 286 322 157 192 221 248 271 313 390 2...

Page 34: ...1 0 70 1 01 1 52 2 07 3 07 4 08 5 09 Code 3400 0611F 3400 0612F 3400 0613F 3400 0614F 3400 0615F 3400 0616F 3400 0617F TAB 3 ISO TABLE OF DELIVERY IN LITRES MIN MEDIUM AND HIGHVOLUME 18 CONICAL NOZZLE...

Page 35: ...one 3 40 4 40 6 20 6 80 8 10 9 20 11 2 direct jet 4 10 5 40 8 30 11 8 15 1 19 1 24 6 TABLE 4 TABLE 4 5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES TABLE OF DELIVERY IN LITRES MIN OFTHE CONICAL NOZZL...

Page 36: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 37: ...X X X X X X X X X X REGULATOR RVA 2 4 5 WAY X X X X X X X X X X X X X X X X X X RM 40 S X X X X X X X X X X X X X GCPElectric X X X X X X X JETS SINGLENON DRIP X X X X X X X X X X X X X X X X X X DOUB...

Page 38: ...X X X X X X X X REVERBERI AR 1064 1053 X PRESSURE GCP RVA X X X X X X X X X X X X X REGULATOR ORION Comet X X X X X X X X X X X X X GCP ELECTRIC X X X X X X X X X X X X X JETS SINGLENON DRIP X X X X X...

Page 39: ...5 1203 X X X X BHA 160 X X X PRESSURE RVA X X X X X X X X REGULATOR ORION Comet X X X X X X GCPELECTRIC X X X X X X JETS P39 X X SINGLENON DRIP X X X X X X X X DOUBLENON DRIP X X X X X X X X TYREMFC X...

Page 40: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Reviews: