background image

8

  unigreen

3.2

NOISE LEVEL OF THE MACHINE

Use earmuffs to protect your ears when using the machine, below you will find the data on
the maximum noise levels during work.

Atomisers with centrifugal fan rotor (Turboteuton)

ACOUSTIC POWER LEVEL 

emitted by the machine: 

123,8 dBA 

in 2nd gear

ACOUSTIC POWER LEVEL AT THE OPERATOR’S POSITION 

emitted by the machine:

103,2

 dBA 

in 2nd gear

Readings taken in accordance with the following standards:
Machines Directive 2006/42/CE
Legislative Decree D.Lgs. n°292 of the 4th of September 2002 concerning the environmental
acoustic emission of machines and equipment for use outdoors.
UNI EN ISO 4254-1:2006.

3.3

STANDARDS OF REFERENCE:

-

 MACHINES DIRECTIVE 2006/42/CE.

-

 D.Lgs. 81/08 Unique text for safety and hygiene in working places.

-UNI  EN ISO 12100-1/Apr.2005 : Machinery safety - Fundamental concepts, general design
principles - Part 1: basic terminology, methodology
-UNI  EN ISO 12100-2/Apr.2005 : Machinery safety - Fundamental concepts, general design
principles - Part 2: Technical principles

-

UNI EN ISO 13857: May 2008 Machinery safety, safe distances to avoid reaching hazardous

areas with upper limbs.

-

UNI EN 349/November 2008: Machinery safety, minimum spaces to prevent crushing of

body parts

-

UNI EN 907/Nov.1998: Agricultural and forestry machinery - Sprayers and spreaders of

liquid fertilizers - Safety.
-UNI EN ISO 13849-1: February 2007: Machinery safety - Fundamental concepts, general
design principles
-UNI EN 982/January 2009: Machinery safety. Safety requisites relevant to systems and their
components for hydraulic and pneumatic transmissions. Hydraulics.
-UNI EN ISO 4254-1/June 2006: Agricultural machines - Safety - Part 1: General requisites
-ISO 11684/1995: Pictograms - general principles.

4

INSTRUCTIONS

To use the machine the personnel must be suitably trained on the basis of the regulations in
force on safety and hygiene at work.
THE USE OF THE MACHINE FOR PERSONS UNDER 18 YEARS OF AGE IS STRICTLY
FORBIDDEN

4.1

DESCRIPTION OF THE MACHINE

The mistblowers consist of a structural steel frame and a polyester tank reinforced with
fibreglass or high-density polyethylene. The frame is hot-galvanised. The tank is easy to
empty and this makes it possible to use the machine even on hillsides.
The pumps are generally diaphragm pumps but in some cases they are fitted with pistons.
The accessories for completing the fitting, non-drip jets and ceramic nozzles make the
UNIGREEN mistblower a highly qualified and efficient piece of equipment.

4.1.1 WORK STATIONS

The use of this machine does not envisage an operator standing constantly near the same,
the operator normally sits in the cab of the tractor.
During calibration and maintenance operations the operator will be working near the machine
at ground level (for all the calibration and maintenance operations refer to the relevant
chapters).
In case of operations  that request the entry to parts of the machines located  at 1,5 mt.
height ,it is advised to use a ladder at rule; the ladder shall be positioned steady on a flat
ground not yielding and with the machine at a standstill and braked.
In some special models with controls above 1.5 metres there is a platform to make these
operations easier.
This platform must only be used with the machine stopped.

Summary of Contents for TurboTeuton P500

Page 1: ...04 2010 USE AND MAINTENANCE MANUAL MISTBLOWERS TURBOTEUTON MOUNTED MISTBLOWERS serie TURBOTEUTON MAIA TT P Polipo P SuperSpalliera RV GDV Read this manual carefully before use GB...

Page 2: ...NSPORTING AND MOVING THE MACHINE 9 4 3 1 MOUNTED ATOMISERS 9 4 4 TRACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7...

Page 3: ...NG POLIPO 4 4 8 NOZZLES NARROW ROWS 26 TABLES FOR CALIBRATING POLIPO 4 4 16 NOZZLES NARROW ROWS 26 TABLES FOR CALIBRATING POLIPO 4 4 8 NOZZLES WIDE ROWS OPTIONAL 27 TABLES FOR CALIBRATING POLIPO 4 4 1...

Page 4: ...work speed over that indicated in the spraying tables in the handbook or too high for the conditions of the terrain use of herbicide booms without an auto levelling system or with the auto levelling s...

Page 5: ...with the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous pictograms Key to the symbols 1...

Page 6: ...se only after having carefully read the instructions on the container 2 3 1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accidents Keep the machine in a su...

Page 7: ...ese machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed mistblowers are not specifically designed for road use Nevertheless many models are also available in...

Page 8: ...components for hydraulic and pneumatic transmissions Hydraulics UNI EN ISO 4254 1 June 2006 Agricultural machines Safety Part 1 General requisites ISO 11684 1995 Pictograms general principles 4 INSTR...

Page 9: ...asn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the lifting gear and the...

Page 10: ...the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the third point tie rod correctly so the...

Page 11: ...the pump FIG 7 NEVER USE THE CARDAN TRANSMISSION IF THE FOLLOWING PROTECTIVE COVERS ARE MISSING TRACTOR POWER TAKEOFF PROTECTIVE COVER CARDAN SHAFT PROTECTIVE COVER FIXED PROTECTIVE COVER ON THE PUMP...

Page 12: ...ion regulator G D auxiliary tap can be used for various accessories it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically...

Page 13: ...djust the corresponding compensator G until you return to the pressure set previously displayed on the manometer open and close the tap of section C and check that the pressure remains constant repeat...

Page 14: ...and after filling stop the pump and put the lever of deviator D back in the working position disconnect pipe T from deviator D b FILLING WITH THE SUCTION FILTER Fig 3 Fig 11 If the 3 way deviator isn...

Page 15: ...for using chemical products are indicated in paragraph 2 2 1 4 12 2PREMIXER ON COVER OPTIONAL Open the cover and pour all of the chemical powder into the filter close the cover and open the supply ta...

Page 16: ...the power takeoff b Check you have filled the circuit washer tank C c Make sure the main control of the pressure regulator is OFF and that all the boom sectors are closed d Turn suction deviator A to...

Page 17: ...to engage the fan rotor gradually This prevents jerky starts due to the inertia of the fan rotor which can have a negative effect on the transmission For the centrifugal clutch to work properly the s...

Page 18: ...way for the configuration of the vegetation All the adjustments are made by hand using knobs and screws When treating particularly wide rows up to 4 m OPTIONAL extendable arms are available The POLIPO...

Page 19: ...4 1 OIL FEED FROM TRACTOR for hydraulic systems Connect the delivery and discharge quick fit coupling to the respective connections respecting the direction of flow The distributor inlet pipe is conne...

Page 20: ...the single jet if it is facing inwards towards the blower group c nozzle second spray when these are pointing towards the outside of the blower group parallel with the non drip valve 6 2 DESCRIPTION...

Page 21: ...the 5 m rows The last line of the table indicates the overall delivery of the fan If the mistblower is fitted with non standard nozzles the spraying tables of the single nozzles per mistblower are on...

Page 22: ...indicated in paragraph 2 2 1 8 1 PROGRAMMED MAINTENANCE TAB N 7 page 33 We recommend using a table of programmed maintenance to follow in time to keep the mistblower in an efficient working condition...

Page 23: ...le from our reseller perform any repairs or contact a specialised workshop During all of the repairs in particular when welding the machine and the circuit must be clean of any residues of chemical pr...

Page 24: ...t and disposal recovery Transport of one s waste to authorised collection centres is allowed exclusively if you are enrolled in the Environmental Management Register 8 7 3 ELECTRICAL AND ELECTRONIC AP...

Page 25: ...1 8 B1606 0015 filter for 18 jet holes 0 8 1002 0110F Ceramic conical nozzle kit Nozzle 0 8 Dif 1 0 Filter 0 8 3400 0400F filter diffuser and seal Nozzle 1 0 Dif 1 0 Filter 0 8 3400 0401F for 18 mm je...

Page 26: ...n 8 getti Lt ha spreading rate table for Turbo Teuton 8 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 390 457 5...

Page 27: ...i Lt ha spreading rate table for Turbo Teuton 8 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 281 329 398 425 4...

Page 28: ...uton 10 getti Lt ha spreading rate table for Turbo Teuton 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 486...

Page 29: ...i Lt ha spreading rate table for Turbo Teuton 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 350 411 494 535...

Page 30: ...on 10 getti Lt ha spreading rate table for Turbo Teuton 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 350 41...

Page 31: ...urbo Teuton GDC 10 getti Lt ha spreading rate table for Turbo Teuton GDC 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working...

Page 32: ...ACITY Lt min 5 cone 1 16 1 40 1 90 2 25 2 65 2 90 3 50 direct jet 1 40 1 70 2 50 3 95 4 7 6 00 7 70 8 cone 1 40 1 80 2 60 2 80 3 40 3 65 4 45 direct jet 1 70 2 20 3 40 4 85 6 00 7 60 9 80 10 cone 1 50...

Page 33: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 34: ...R GCP 2 ELECTRIC PRES X X X X DISTRIBUTOR POLIPO 4 4 X X X X ACCESSORIES POLIPO 5 5 X X X X SUPER SPALLIERA 4 4 X X X X RV GDC 5 5 X X X SINGLE 18 X X X X NOZZLES DOUBLE 18 X X X X NOZZLE TIPS Ceramic...

Page 35: ...unigreen 35...

Page 36: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Reviews: