P=1 is for Aalrm and listen 

P=2 or 3 is the second\ the third listen number. 

e.g. 

A000000,003,1,136xxxxxxxx 

Message replied after successful setting

Set Telephone OK!

 

After it’s set successfully, once there is an alarm happened, the 
device  will  alert  to  Alarm  Number  and  Tracking  System  by 

message. 

If you dial with one of these three numbers you set, it can be 

connected  automatically  after  the  3th  rings.  Then  you  can 

listen the voice in the vehicle.

 

2.5    Over-Speed Alarm Setting (005) 

Message format

  A******,005,XXX 

XXX=[000,200] (unit: km/h)XXX=00 is close the function. 

e.g. 

A000000,005,020

 

Message replied after successful setting: 

Set Over speed (20) 

KM OK!

 

If the vehicle is over speed you set, it will send alarm message 

to Alarm Number: 

20 KM/H Over speed! 

2.6    Geo-Fence Setting(006) 

Message format

A******,006,XX 

XX =[00-50] (Unit:100m) . 

When XX=0, e-Fence is OFF. And the maximum limited value 

of XX is 50*100=5000m.    e.g. 

A000000,006,10

 

Reply: 

Set Distance (1000)M OK! 

When user is out of the bound region (e.g. 1020m), a prompt 

Summary of Contents for UT06

Page 1: ...UniGuard Technology Limited www uniguardgps com UT06 OBDII Plug Play GPS Tracker User Manual ...

Page 2: ...y Flashing per three seconds once which indicates GPS is obtaining orientation It is still on which indicates GSM has registered and GPS has obtained the orientation It s working well If it is on for 0 1 second then off for 0 1 second more than 3 minutes please make sure SIM card inserted well Without SIM card the device cannot work 2 SMS Operation Instruction SMS Format A cmd param1 param2 1 is t...

Page 3: ... New Password e g A000000 001 123456 Note 000000 is the old password 123456 is the new password Reply Set Password OK 2 3 Real time return setting 002 Message format A 002 XXX XXX 0 is for STOP value of XXX is within 15 64800 seconds e g A000000 002 30 Message replied after successful setting Set time interval 30 OK Message contains position information will be sent in every 30 seconds after succe...

Page 4: ...matically after the 3th rings Then you can listen the voice in the vehicle 2 5 Over Speed Alarm Setting 005 Message format A 005 XXX XXX 000 200 unit km h XXX 00 is close the function e g A000000 005 020 Message replied after successful setting Set Over speed 20 KM OK If the vehicle is over speed you set it will send alarm message to Alarm Number 20 KM H Over speed 2 6 Geo Fence Setting 006 Messag...

Page 5: ...N Access Point NAME 012 Message format A 012 APN Length of APN is limited within 100 characters E g A000000 012 CMNET CMNET is the APN of China Mobile 3 2 Set the IP and Port of GPRS Server 010 Message format A 010 IP PORT e g A000000 010 104 243 132 242 5500 104 243 132 242 is the IP of GPRS_server 5500 is the port of GPRS Server application 3 3 Open GPRS function 011 Message format A 011 X note ...

Page 6: ...ack GPRS setting parameters You can check whether the parameter set correctly by it 1 Device ID 2 APN Contact SIM provider to get correct APN 3 Server IP address 4 Server port 5 GPRS open status 0 off 1 on 6 GPRS connecting status 0 Internet is not connected 1 connected 7 GSM signal value 1 31 if it s less than 13 the signal is too weak and the device can t upload data to server automatically ...

Reviews: