The AR-3600I uses a design based on a 25-tap toroidal autotransformer. The 
toroidal design assures minimal leakage of stray magnetic fields in a highly efficient, 
compact package. 

The AR-3600I’s circuitry monitors the incoming line voltage with each cycle. If a 
voltage change requires that a different tap be selected, the new tap is electronically 
switched in precisely at the zero-crossing, to avoid distorting the AC waveform. If 
necessary, the AR-3600I can switch taps as often as once each cycle. Most 
commercial voltage regulators using multiple-tapped transformers switch taps with 
relays at uncontrolled times, thereby creating voltage spikes! And unlike voltage 
regulators that employ Ferro resonant transformers, the AR-3600I is not sensitive to 
small errors in line frequency, making it ideal for use with generators. 

The AR-3600I has six convenience outlets on its rear panel, and one on the front 
panel. All outlets are regulated, spike-suppressed, and filtered against RFI with a 3-
pole filter. There are no controls except a master circuit breaker, which serves as an 
on-off switch. One or more units may be turned on remotely, either simultaneously or 
in sequence, by switching an internally-derived DC control line.

The AR-3600I is housed in a three space (5.2” high and 17” deep) rack-mount 
chassis, and weighs only 53 lbs (24 kg). It is made of extremely rugged heavy gauge 
black powder coat steel. Allow it to be secured in both front and rear. It comes 
equipped with a male IEC-309 power input and a female IEC-309 power link output 
sockets.

AR3600I LIMITATIONS

AC power is, to some extent, unpredictable. The available voltage may vary 
from place to place and from moment to moment. The waveform may not be a 
perfect sine wave, and high or low frequency noise may be present. AC power 
also varies from country to country in terms of voltage and frequency.

The AR3600I is intended to reduce to the greatest extent possible, the impact 
of these irregularities. However, you should be aware that there are certain 
things it cannot do. These include, but are not limited to:

1. Protecting against direct lightning strikes.

2. Protecting from complete loss of power (blackouts).

3. Performing frequency conversion from 50Hz to 60 Hz or vice versa.

4. Isolating ungrounded equipment.

General Information

    Installation    Operation    Specification

AR3600I

AC LINE VOLTAGE REGULATOR

Summary of Contents for AR3600I

Page 1: ...ex 01 General Information 04 Installation 05 Operation 10 Specification INPUT VOLTAGE OUTPUT VOLTAGE L N REGULATED OUTPUTS 5 OVER IN REGULATION 5 UNDER OUTPUT CURRENT UNiKA P R O F E S S I O N A L A U D I O AR 3600 I INPUT RANGE 88 264VAC 30A MAXIMUM O T R S E S S E E R T P L I N E R E G U L A T O R 1 2 0 V 3 0 A O U T P U T A C P R O F E S S I O N A L A U D I O ...

Page 2: ...laceable parts inside Please contact the authorized dealer for any requirements on technical support 3 The AR3600I is a complex electronic instrument with various wiring options You cannot simply plug in and go Take the time to read this manual especially the sections on Installation and Operation For any questions in doubt please contact the authorized dealer for further assistance GENERAL INFORM...

Page 3: ...e Figure 1 The AR 3600I can handle loads totaling up to 30 amperes as long as the input voltage is equal to or above 120 volts low range or 240 volts high range For voltages below those levels its capacity must be derated at approximately one quarter ampere per volt See Figure 2 below In live performance situations where each act requires a special AC configuration accidental connection to incorre...

Page 4: ...n off switch One or more units may be turned on remotely either simultaneously or in sequence by switching an internally derived DC control line The AR 3600I is housed in a three space 5 2 high and 17 deep rack mount chassis and weighs only 53 lbs 24 kg It is made of extremely rugged heavy gauge black powder coat steel Allow it to be secured in both front and rear It comes equipped with a male IEC...

Page 5: ...able is highly recommended for best flexibility and abrasion resistance It is permissible to use 4 conductor cable but it is not necessary to do so and is not recommended EFFECTS OF CABLE LENGTH When dealing with high currents such as those handled by the AR3600I the supply cable itself must be considered part of the load As such the length gauge and temperature rating of the insulation must be ta...

Page 6: ...rews which may fit if forced but will strip the threads To avoid marring the front panel finish use plastic washers under the screw heads OPERATION FRONT PANEL FEATURES INPUT VOLTMETER Large size 7 segment 3 digit LED display indicate the input voltage in either of two ranges The appropriate range is selected automatically OUTPUT AMMETER Large size 7 segment 3 digit LED display with decimal indica...

Page 7: ...o produce the rated 120V 30A at the output Therefore safety considerations require a separate 15A breaker which is active only when a high range 170 volts or higher supply voltage is used This breaker trips by popping out If it trips decrease the load on the AR3600I and push it in to reset POWER SWITCH This is the AR3600I s main on off switch It is actually a 30 ampere magnetic trip circuit breake...

Page 8: ...red up simultaneously Using such a delayed sequence can avoid blowing a house breaker when all the A3600Is are powered from the same circuit See the section on Remote Delayed Operation later in this manual for details Note No connections or jumpers are needed for normal AR3600I operation REGULATED OUTLETS There are 7 regulated outlets on the AR3600I one in front and the balance in the rear While t...

Page 9: ...R3600Is remote turn on in delayed sequence A built in delay of approximately a quarter second is automatically provided to stagger the potentially large inrush currents that occur when certain types of equipment are powered up simultaneously Using such a delayed sequence can avoid blowing a house breaker when all the AR3600Is are powered from the same circuit To create a remote delayed sequence al...

Page 10: ...n also foul switch contacts and degrade wiring insulation They are an unavoidable component of electric power They are caused unpredictably by electric motors switching on or off on the premises or outside utility company maintenance operations lightning strikes and other factors Spikes also called surges or transients are absorbed by special components in the AR3600I to provide safe voltage level...

Page 11: ...nd line to ground Clamping Voltage line to neutral neutral to ground 250 Volts peak 130V rms 184V peak Clamping Voltage line to ground 500 Volts peak Response time 1 nanosecond Maximum surge current 5 000 amps 8 x 20 ps pulse Maximum spike energy 455 joules total Noise attenuation Transverse 50 dB 1 to 120 MHZ Dimensions 132mm H x 483mm W x 428mm D Weight 24Kg Construction All steel chassis powder...

Page 12: ...ules not included to terminate stranded wire in coupling connector General Information Installation Operation Specification AR3600I AC LINE VOLTAGE REGULATOR Figure 7 Blue 32A 3 Contact High Current In line Socket Figure 8 Blue 32A 3 Contact High Current In line Plug A male IEC 60309 cable mounting power inlet is also included with your AR3600I Neutral N Live Hot L Ground G Live Hot L Ground G Neu...

Page 13: ......

Page 14: ...P R O F E S S I O N A L A U D I O ...

Reviews: