SPECIFICATIONS

UNiKA

 MT-600Q

M

T-600Q

page 9

Dimensions 

Weight 

Input Connections 

Output Connections 

Input Impedance 

Input Sensitivity 

Output Power, 8 ohms 

Output Power, 4 ohms 

Bridged Output Power, 16 ohms 

Bridged Output Power, 8 ohms 

Stable into 

CMRR 

Frequency Response 

Hum and Noise 

Total Harmonic Distortion (THD) 

Slew Rate 

Damping Factor 

Transformer Type 

Power Requirements 

1.75”H x 19.0” W x 13.5”D ; 44.5mm x 482.6mm x 190.5mm

19.8 lbs., 9.0kg.

¼” TRS (balanced/unbalanced); Euroblock (balanced/unbalanced)

Multi-Way Binding Post

44k ohms (balanced); 22k ohms (unbalanced)

1V for full power output into 8 ohms

4 x 100Watts/Channel RMS

4 x 140Watts/Channel RMS

2 x 200Watts/Channel RMS

2 x 280Watts/Channel RMS

2 ohms (stereo), short term
4 ohms (bridge), short term

>60dB (typical @ 1kHz)

10Hz to 40kHz, +/- .5dB

>100dB below clipping

<0.05% (typical)

>20V/uS

>100

Toroidal

100VAC 50Hz 1000 WATTS (max.)
120VAC 60Hz 1000 WATTS (max.)
220VAC 50Hz 1000 WATTS (max.)
230VAC 50Hz 1000 WATTS (max.)
240VAC 50Hz 1000 WATTS (max.)
Export units configured for country of destination.

Summary of Contents for MT Series

Page 1: ...tion 02 03 Front Panel 04 Rear Panel 05 Set Up 07 Operating Modes 08 Protection 09 Specifications 0dB 2 5 9 13 18 22 26 32 46 8 0dB 2 5 9 13 18 22 26 32 46 8 0dB 2 5 9 13 18 22 26 32 46 8 0dB 2 5 9 13 18 22 26 32 46 8 CHANNEL 1 CHANNEL 3 CHANNEL 2 CHANNEL 4 PROTECT PROTECT CLIP CLIP CLIP CLIP SIGNAL SIGNAL SIGNAL SIGNAL UNiKA PROFESSIONAL STEREO AMPLIFIER MT 600Q P R O F E S S I O N A L A U D I O ...

Page 2: ...ements supplémentaries situés dans le guide Ce symbole est utilisé pour indiquer à l utilisateur qu il trouvera d importantes instructions importantes sur l utilisation et l entretien de l appareil dans la littérature accompagnant le produit Dieses Symobl soll den Anwender vor unisollierten gefährlichen Spannungen innerhalb des Gehäuses warnen die von Ausreichender Stärke sind um einen elektrische...

Page 3: ...he power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the unit C The appliance has been exposed to rain or water D The fixture does not appear to operate normally or exhibits a marked change in performance Congratulations and thank you for purchasing MT 600Q amplifier This amplifier is representation of UNiKA s continuing commitment to produce the ...

Page 4: ...reduce the risk of damage to your speakers and amplifier This LED may glow when the unit has been turned off this is normal 9 Channel 2 Signal Indicator This green LED will glow when there is audio signal connected to channel two s input connector 10 AC Power Switch MT 600Q power amplifier has a front panel AC mains power switch 11 Channel 3 Signal Indicator This green LED will glow when there is ...

Page 5: ...lows the amplifier operating mode from either stereo or mono bridge selection Amplifiers are factory configured for Stereo Mode See section on Mode Selection for more information 21 AC Power Input IEC AC power inlet connector plug this cable in to a standard 110Vac or 220Vac wall outlet Be sure that supplied voltage matches that of the required voltage of your amplifier Never plug your amplifier i...

Page 6: ...s are made to channel one and channel two outputs for Stereo Mode or across the red terminals of channel one and channel two for Mono Bridge Mode please follow the same connections aforementioned on the channel three and channel four for Stereo Mode or Mono Bridge Mode IMPORTANT NOTICE Although a speaker will operate with the positive and negative leads plugged into either terminal on the amplifie...

Page 7: ... CONNECTOR Figure 7 When connecting your speakers to the amplifier using spade connector unscrew the red and black caps on the binding post be sure not to completely remove or unscrew the red and black caps Insert the spade connector into the binding post and tighten the caps down on the spade connector To reduce the risk of shock or damage to your amplifier be sure that the wire connected to one ...

Page 8: ...m Bridge Mode 120VAC 60Hz 1200VA FUSE T250V 10A L CAUTION REPLACE WITH SAME TYPE FUSE AND RATING ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE TO RAIN OR MOISTURE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN Designed and developed in the USA Manufactured in Taiwan Figure 9 Typical Stereo Output Connections MT 600Q REAR PANEL CH 1...

Page 9: ...ly event the heatsinks should reach 194 degrees Fahrenheit the amplifier will mute until it cools down enough for safe operation Make sure there is adequate ventilation around the heatsinks if you plan on rack mounting the MT 600Q in an enclosed space 3 The MT 600Q is fully protected from shorts opens over current and over voltage A relay disconnects the outputs under any of these fault conditions...

Page 10: ...ower Requirements 1 75 H x 19 0 W x 13 5 D 44 5mm x 482 6mm x 190 5mm 19 8 lbs 9 0kg TRS balanced unbalanced Euroblock balanced unbalanced Multi Way Binding Post 44k ohms balanced 22k ohms unbalanced 1V for full power output into 8 ohms 4 x 100Watts Channel RMS 4 x 140Watts Channel RMS 2 x 200Watts Channel RMS 2 x 280Watts Channel RMS 2 ohms stereo short term 4 ohms bridge short term 60dB typical ...

Page 11: ...page 10 Important Precautions Introduction Front Panel Rear Panel Set Up Operating Modes Protection Specifications UNiKA MT 600Q ...

Page 12: ...P R O F E S S I O N A L A U D I O ...

Reviews: