Base Amp -
Provides selection for the Base Amperage during the Pulse Welding cycle.
Peak Amp -
Provides selection for the Maximum Welding Amperage required during welding.
Up Slope Time -
Sets the transition time from Start Amperage to Welding Amperage
Start Amp -
Provides selection for the amount of amps required at the start of the weld.
Front Panel Operation - Weld Program Sequence Control Razor 2OO TIG-MMA
Parameter selection: Select by pushing selector pad to
cycle through to illuminate the icon of the parameter
required. Each push of the selector pad will move the icon
illumination in a clockwise cycle.
Pre Gas Timer -
Provides selection for gas flow time prior to the arc starting.
Turn the Encoder to set
the Pre-Gas Time
(Range is 0-10 Sec)
Pre Gas Time: Select by pushing selector
pad to cycle through to illuminate the Pre
Gas Timer icon.
The value selected shows on the digital
display. It is the length of time the gas
will flow before the arc starts.
Indicates Action
Selector Pad
Turn the Encoder to set
the Start Amp value
(Range is 10-200A)
Pre Gas Time: Select by pushing selector
pad to cycle through to illuminate the Start
Amp icon.
The value selected shows on the digital
display. It is the amount of amps the
machine will deliver at the start of the
welding sequence.
Turn the Encoder to set
the Up Slope value
(Range is 0-60 Sec)
Up Slope Time: Select by pushing selector
pad to cycle through to illuminate the
Up Slope icon.
The value selected shows on the digital
display. It is the amount of time the
welding current takes to climb from
start amperage to welding amperage.
Turn the Encoder to set
the Peak Amp value
(Range is 10-200A)
Peak Amp: Select by pushing selector
pad to cycle through to illuminate the Peak
Amp icon.
The value selected shows on the digital
display. It is the maximum set value of
amperage the machine will deliver.
Turn the Encoder to set
the Peak Amp value
(Range is 10-200A)
Base Amp: Select by pushing selector
pad to cycle through to illuminate the Peak
Amp icon.
The value selected shows on the digital
display. It is the set value of amperage
the machine will deliver during the Base
Amp period of the pulse cycle.
4.
Weld Program -
Provides selection weld program parameters