Weekly or Holiday UV Cleanup Procedure
Perform the
“UV Daily Cleanup Procedure”
plus the following:
1. Rinse the hose kit with
UV Klean
by either of the following methods:
2. Put both ends of the hose into a container with a small amount of
UV Klean
and energize the pump
by running the
iColor coater
. Allow the pump to circulate the
UV Klean
for one to two minutes.
3. Disconnect the hoses from the pump, then pour a small amount of
UV Klean
into each hose and
slosh back and forth until the
UV Klean
flows freely in the hoses and then discard the
UV Klean
into a cup with a paper towel and dispose of in the trash (no biohazard will exist).
4. Remove the Coating Unit seals from the backing plate kit by the spring clip, manually clean the
seals and the ends of the rollers with
UV Klean
and reinstall.
CAUTION:
Never run the equipment with the seals removed as this will cause damage to the
rollers, which is NOT covered by the roller warranty!
5. Remove the coating drip pan and clean with
UV Klean
.
6. Remove the doctor blade and clean with
UV Klean
.
7. While you have the Doctor Blade and the Drip Pan removed, completely clean the Impression roller
with
UV Klean
. Reinstall drip pan & doctor blade.
8. Dispose of all coating, rags and cleaner as directed per your local regulations.
9.
Pour the contents of the Vac into a disposable container filled with rags or paper towels
and
dispose of per your local regulations.
10. Turn the coating unit controls to the
“END OF DAY POSITION”
to prevent flat spots on the rollers.
11. Turn the Main Power disconnect to the OFF position!
Keep It Clean with Komplete UV Klean
It is extremely important to properly clean and maintain your
iColor coater
.
UniNet
recommends
UV Klean
as a part of your daily UV coating clean-up procedure.
• Water miscible
• Low VOC
• No oily residue
• Meets US & Canadian environmental regulations