REMOVING THE TONER HOPPER
45. Remove all four corner screws that hold the toner hopper and cartridge together.
OKIDATA B6300
•
TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS
© 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only.
UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact techsupport@uninetimaging.com
www.
uninet
imaging.com
46. Toner hopper removed. Note the two foam seals located at
the bottom of the hopper. These foam seals surround holes
where toner passes through to the developer roller. Residual
toner can build up in these areas, so it is important to clean
thoroughly before reinstalling the hopper.
47. Clean the hopper and toner cartridge using compressed air
or a vacuum. Refill and reassemble following the previous
steps in reverse.
NOTE
: A new replacement smartchip must be fitted after