11. With a small common screwdriver, press the entire plate
towards the edge of the developer roller cavity, and lift up. The
plate should come loose.

12. Gently pry out the roller plate from the cartridge. The foam
seal, and possibly a plastic flat washer will come out with it. Be
careful not to damage the foam seal, or loose the flat washer.

13. Remove the developer roller.

Be careful not to damage or lose the flat washers on the roller.

14. It is highly recommended that the doctor blade be cleaned.
Failure to do so will cause streaking. The doctor blade can be
cleaned with out removing it. Dampen a cotton swab with alco-
hol, and clean the blade. Be careful not to press too hard and
damage the blade. If the blade has a heavy buildup of toner on
it, clean it with acetone, and then alcohol. Removing the blade
is difficult because of the foam seals attached. If the seals are
torn, the cartridge will leak. That is why we do not recommend
it. Once replacement doctor blades are available, they will
have to come with replacement foam.

XEROX WORKCENTRE PE120 

CARTRIDGE REMANUFACTURING INSTRUCTIONS

© 2010 UniNet Imaging Inc. All trademark names and artwork are property of their respective owners. Product brand names mentioned are intended to show compatibility only.

UniNet Imaging does not warrant downloaded information. Unauthorized sale, reproduction or distribution of this article is prohibited. For additional support, please contact techsupport@uninetimaging.com

www.

uninet

imaging.com

Summary of Contents for XEROX WORKCENTRE PE120

Page 1: ...ames and artwork are property of their respective owners Product brand names mentioned are intended to show compatibility only UniNet Imaging does not warrant downloaded information Unauthorized sale reproduction or distribution of this article is prohibited For additional support please contact techsupport uninetimaging com www uninetimaging com ...

Page 2: ... Remove the end cap XEROX WORKCENTRE PE120 CARTRIDGE REMANUFACTURING INSTRUCTIONS 2010 UniNet Imaging Inc All trademark names and artwork are property of their respective owners Product brand names mentioned are intended to show compatibility only UniNet Imaging does not warrant downloaded information Unauthorized sale reproduction or distribution of this article is prohibited For additional suppo...

Page 3: ...t follow the cleaning methods recommended by the manufacturer If the PCR is an OEM we recommend it be cleaned with your standard PCR cleaner XEROX WORKCENTRE PE120 CARTRIDGE REMANUFACTURING INSTRUCTIONS 2010 UniNet Imaging Inc All trademark names and artwork are property of their respective owners Product brand names mentioned are intended to show compatibility only UniNet Imaging does not warrant...

Page 4: ...ttached to the metal bar Wipe this blade down with a clean lint free cloth before re installing It is very important that the PCR cleaner be cleaned Vacuum or blow off any residual toner from the foam felt XEROX WORKCENTRE PE120 CARTRIDGE REMANUFACTURING INSTRUCTIONS 2010 UniNet Imaging Inc All trademark names and artwork are property of their respective owners Product brand names mentioned are in...

Page 5: ...lade Be careful not to press too hard and damage the blade If the blade has a heavy buildup of toner on it clean it with acetone and then alcohol Removing the blade is difficult because of the foam seals attached If the seals are torn the cartridge will leak That is why we do not recommend it Once replacement doctor blades are available they will have to come with replacement foam XEROX WORKCENTRE...

Page 6: ... carefully at the picture of the gears Each gear must fit in this exact way The gears labeled in order of installation XEROX WORKCENTRE PE120 CARTRIDGE REMANUFACTURING INSTRUCTIONS 2010 UniNet Imaging Inc All trademark names and artwork are property of their respective owners Product brand names mentioned are intended to show compatibility only UniNet Imaging does not warrant downloaded informatio...

Page 7: ... the shaft is in the PCR holder XEROX WORKCENTRE PE120 CARTRIDGE REMANUFACTURING INSTRUCTIONS 2010 UniNet Imaging Inc All trademark names and artwork are property of their respective owners Product brand names mentioned are intended to show compatibility only UniNet Imaging does not warrant downloaded information Unauthorized sale reproduction or distribution of this article is prohibited For addi...

Page 8: ...e that can change the personality of the chip across the full line This will enable you to test the cartridge in your test machine and than change the chip to work in your customer s machine if different XEROX WORKCENTRE PE120 CARTRIDGE REMANUFACTURING INSTRUCTIONS 2010 UniNet Imaging Inc All trademark names and artwork are property of their respective owners Product brand names mentioned are inte...

Page 9: ...UniNet Imaging Inc All trademark names and artwork are property of their respective owners Product brand names mentioned are intended to show compatibility only UniNet Imaging does not warrant downloaded information Unauthorized sale reproduction or distribution of this article is prohibited For additional support please contact techsupport uninetimaging com www uninetimaging com ...

Reviews: