UPS338-01-00 PowerWAVE 8000-RI DPA User Manual Dated 5 April 2013
2-1
2
General Description
2.1
Reliability and Quality Standards
Congratulations on your purchase of the PowerWAVE 8000-RI DPA.
Using a unique modular construction the PowerWAVE 8000-RI DPA represents a completely new generation
of medium power, 3 phase UPS-Systems, incorporating the latest technological developments in power
engineering. High reliability, upgrade ability, low operating costs and excellent electrical performance are only
some of the highlights of this innovative UPS solution.
Uninterruptible Power Supplies Ltd specialises in the design, building, installation and maintenance of
Uninterruptible Power Systems. This compact and powerful UPS is just one example of our wide range of
state-of-the-art power protection devices and will provide your critical equipment with a steady and reliable
power supply for many years.
The criteria and methods which are used in the design, manufacture, and maintenance of Uninterruptible
Power Supply systems are certified to International Standard ISO 9001/EN 29001 and ISO 14001. A full UPS
Specification is given in Chapter 8 of this manual.
2.2
PowerWAVE 8000-RI DPA System
The PowerWAVE 8000-RI DPA is a truly modular, rack-mountable system based on 10kVA or 20kVA UPS
modules. The system can be based around a single 10kVA or 20kVA module or two (or more) modules
connected in parallel and configured to operate as a redundant or increased capacity system.
The system comprises a 19 inch sub-rack assembly containing the UPS Module(s), switch panel, battery
tray(s), power connectors, and a range of communication I/O facilities.
2.3
System configuration
Figure 2.1 illustrates the available sub-rack configurations populated with either 1 or 2 UPS modules.
Thanks to the advanced PowerWAVE 8000-RI DPA system design, it is possible to operate a dual module
system with only a single module fitted and add the second module at a later time to increase the system
capacity along with a future increase in load demand. This ‘hot-swappable’ design also allows modules to be
exchanged while the equipment is running during troubleshooting and repair procedures without the need to
put the load to ‘bypass’ (of course, depending on system redundancy and demanded load).
Key Point:
All the modules fitted within a cabinet must be of the same rating – i.e. it is not possible
to mix 10kVA and 20kVA modules in the same parallel system.
Summary of Contents for PowerWAVE 8000DPA RI
Page 1: ...User Manual PowerWAVE 8000DPA RI Pioneering solutions for total power protection ...
Page 2: ...UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 4: ...UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 8: ... iv UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 10: ...1 Safety 1 2 UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 16: ...2 General Description 2 6 UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...
Page 42: ...3 Installation 3 26 UPS338 01 00 PowerWAVE 8000 RI DPA User Manual Dated 5 April 2013 ...