Specification
MODEL
CPF-M400S
CPF-M400U
CPF-M600S
CPF-M600U
CAPACITY
400 VA / 200W
600VA / 300W
Voltage
120 VAC or 220/230/240VAC
Frequency 50/60
Hz
INPUT
Phase Single
Voltage Range
120 VAC or 220/230/240VAC ± 10%
Frequency
50Hz or 60 Hz ± 1Hz
OUTPUT
(Inverter Mode)
Waveform Modified
Sinewave
TRANSFER TIME
2-6ms
Typical
Battery Type
12v/4.5Ah*1
or equal capacity
12V/5Ah*1
or equal capacity
Recharging Time
16 hours max.(Recharge to 90% Capacity)
BATTERY
Backup Time (at a PC
load) typical 100W
10-15 minutes
10~18 minutes
DISPLAY
LED
Power on, Backup, Fault
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding every 0.5 second
AUIBLE ALARM
Fault Continuous
Sounding
PROTECTION
Full Protection
Overload, Overcharge, Short Circuit and
Modem/Phone Line Surge Protection
Dimension (DxWxH)
300X125X85 (mm)
Net Weight
3.2kgs
3.5kgs
Schuko
All for surge protection, 3 plus battery backup
PHYSICAL
Outlets
French
All for surge protection, 3 plus battery backup
Operation
Temperature
0-40
℃
ENVIRONMENT
Operation Humidity
0%-90%
Smart RS-232
Windows family, Sun Solaris, IBM Aix, Compaq
True64, UnixWare, FreeBSD, HP-UX, Linux
and MAC
INTERFACE
USB Port
(Optional, for
CPF-M400U &
CPF-M600U)
Windows family and MAC