The user can exit to the parent menu using [ENT~] key to apply the changed value after
finishing the setting while using [F4(←)] key to cancel input during setting.
.
3.7.4. Wiegand
When the user selects [ENT~]
[5. Terminal]
[4. Wiegand] in the initial screen
◆
, the
following screen will appear.
▶
Initial setting: Identical with the screen at the left
This is the menu that configures the Wiegand Output.
It is used only when a separate controller operating with Wiegand input is mounted. Upon
successful authentication, it transmits the data to the terminal’s Wiegand port in the
following form;
2.None
This is the normal case; Wiegand Outport is not used in this case.
3.26bit
It transmits “Sitecode[1byte] + user ID[2byte]”, so the user ID is set to 4
digits or less.
Example) In the case of SiteCode:045(2Dh), UID:6543(198Fh), it is
transmitted as ‘1 00101101 0001 1001 10001111 0’
4.34bit
It transmits “Sitecode[1byte] + user ID[3byte]” so the user ID is set to 7
digits or less. In case of an 8-digit user ID, “user ID[4byte]” is
transmitted without Sitecode.
Example) In the case of SiteCode:001(1h), UID:123456(1E240h), it is
transmitted as ‘0 00000001 00000001 11100010 01000000 0’
5.Custom
It can be set in the server as the settings under the user’s definition
only. The setting type can only be inquired at the terminal.
However, when Bypass is checked, regardless of Wiegand Out settings, it transmits the
data received by Wiegand Inport at the time when authentication was successful to the
Widgand Outport as it is.
The user can exit to the parent menu using [ENT~] key to apply the changed value after
finishing the setting while using [F4(←)] key to cancel input during setting.
3.7.5. Card Reader