LUBRICATION
Lubrication of the machine has been checked at the factory during the
testing period. However, a double check of all the lubrication fittings should be
made to familiarize the maintenance staff of all the lubrication points. Be sure
to check the oil level in the reducer gear box before power is applied.
CLEANING
Clean all equipment whenever it will be idle for a period in excess of the usable
life of the coating material, or at last once daily.
The most efficient way to clean the coating head is to use as much of the
coating material within the rolls while coating product. Any material left in the rolls
when production is over will be wasted. If both coating heads (top and bottom) were
being used, you do not need to move the top vertical adjustment. If only the top
coating head was used, ra
ise the top coating assembly to about 3”; stop the coater
and insert the cleanup pan. The cleanup pan and catch pan may be lined with
plastic or paper; this will make it easier to clean up when the wasted coating
material and clean up material have been dumped. If you are cleaning both the top
and bottom coating heads, do not make any vertical adjustments. Stop the coater by
moving the reversing switch to neutral and raise lexan hood for access on the
backside of the coater. Once the lexan hood is open, the machine will not be able