Page 18
Cleaning (continued)
to be started. Add cleanup material to one or both coating assemblies in
between the doctor and coating rolls. Close the lexan hood and move the doctor
roll against the coating roll, just as you would to apply a minimum coating. Start the
roller coater in the forward position. Allow the cleanup material to revolve with the
coating material for several minutes. After several minutes, reverse the direction of
the coating rolls by moving the reversing drum switch to reverse. This will allow all
material between the rolls to be squeezed out from the bottom of the rolls into the
cleanup pans or catch tray.
Repeat adding the cleanup material approximately 2-3 more times at which
time all rolls should be cleaned of any coating material and only have a small
amount of residue of cleanup material on them. IMPORTANT: Adjust doctor roll
away from the coating roll to ensure they are not touching. This may be done while
rolls are still revolving. Leaving rolls together will cause a flat spot on rubber coating
rolls.
STOP/POWER DOWN THE MACHINE TO PREVENT AN ACCIDENT
. Wipe
the rolls clean and loosen the seal plates.
NEVER WIPE THE ROLLS WHILE THEY ARE ROTATING.