Page 27
Depending on the set up of the machine, if you turn the coupling clockwise/or
counterclockwise, it will move the doctor roll side that is furthest away from the
unifeed handle either closer or farther away from the coating roll. Likewise, if you
only turn the unifeed handle you can move the side closest to the handle either
closer or farther away from the coating roll.
To parallel the rolls we recommend using a .015 feeler gauge. When paralleling
the rolls always make sure that the machine is turned off for safety purposes.
SEAL PLATES
The UHMW seal plates ensure that the coating material is held between the
coating roll and doctor roll. These seal plates are spring loaded and should be
hand tightened against the rolls. The UHMW portion of the seal plate is a wear
item and is screwed to the metal backer plate by self-tapping screws.