53
Kind 3 (42-55)
Item
Description
Default
Instruction
42
43
44 Volume of DTMF dialling
40
00-63 scales (standard value: 40, unit: 1dB)
Application: If DTMF signal of CO line is too
high or too low.
45 Volume of CO incoming call
40
00-63 scales (standard value: 40,unit: 1dB)
Application: If volume of incoming call is too
high or too slow.
46 Whether to print the status of incoming call
1
1: Yes
0: No
RS-232 interface is needed.
47 Auto route selection (ARS) group
00
00: Invalid
01-09 groups
Application: Using LCR to route the cheapest
cost.
Related programs: K2 item 133, K3 item 94, 98;
function no. 22-25
48 Shortest time of incoming call signal
25
1-9999 x 0.01 ms
Application: For non-ringing incoming call or
specification of connecting equipment
Notice
: If incoming call signal is square wave,
it should be programmed at " 1 ".
49
Shortest time from CID signal to incoming
call ringing signal
1
0-9999 x 3.333 ms
Description: Time length from end of receiving
DTMF Caller ID to ringing.
Width of DTMF signal:
50
Longest time from CID signal to incoming
call ringing signal
400
51 Width of Caller ID signal
300
52 Sending the warning tone of call-waiting
1
0: No
1: Yes (Match to program K2 item 122)
Application: Alert to the busy station there’s
another incoming call waiting by sending the
warning tone.
53 Duration for CO to CO call-forwarding
0
0: CO to CO is prohibited
1-9999 seconds
Related function no.18, 23, 96
54 Duration for Outgoing call
0
0: No limit on communication duration
1-9999 seconds
Application: To control this CO line duration.
55 Duration for Incoming call
0
Trunk
P BX
Volume
Adjus tme nt
S ta tion
Time
Time