    2-1. Registration of RF Card 

 

Code :    (R)              (1)              (*)              RF Card 

   

 Open battery cover     

 

 Press “R” button in PCB for one second and you can hear “Bee” sound 

 Press “1” and “*”  button in keypad and place target RF card to near signal receiving 

part of the front body of the door lock   

 When the card is registered properly, you hear sound “Bee-Ri-Rick”. 

 

 When you try to register card already registered, you hear “Bee-Bee-Bee” sound and no 

registration is made. 

  The RF card can be registered one by one (Max. 20 cards). If you want to register 

multiple cards at one time, please place the card near signal receiving part in turn. 

 In multiple registration of the cards, this process will stop and power off automatically 

unless placing next card within 5 seconds. 

 

    2-2. Access by RF Card

 

 

Code :  (START)       RF Card 

 

 Press “START” button in the outside body (Blue LED on) 

 If you do not place card for 5 seconds, this mode will be stopped automatically. 

 Place registered card near signal receiving part   

 You can hear voice sound “It’s open”   

 Blue LED goes off and Door will be automatically locked again after 6 seconds 

 You hear voice message “It’s lock” when Door is automatically locked. 

 If the unregistered card is used, you can hear the sound “Please try again”. If the 

unauthorized access trial is made more than 3 times, all the operations of the doorlock 

Summary of Contents for CFR-170

Page 1: ...User Manual Model CFR 1700 Unipion Co Ltd...

Page 2: ...of password 2 RF Card Registration 2 1 Registration of RF Card 2 2 Access by RF Card 2 3 Deletion of RF Card 3 Registration Deletion of Remote Control 3 1 Registration of remote control 3 2 Access by...

Page 3: ...number date of birth or 4 digits number etc to avoid any misuse by unauthorized person 1 2 Access by password Code Password 4 12 digits Press button in keypad No entry of the key for 5 seconds goes t...

Page 4: ...card near signal receiving part in turn In multiple registration of the cards this process will stop and power off automatically unless placing next card within 5 seconds 2 2 Access by RF Card Code ST...

Page 5: ...rt Open battery cover Press R button in PCB for one second and you can hear Bee sound Press 2 and button in keypad Press the button in the remote control toward the antenna In case the remote control...

Page 6: ...ess R button in PCB and you can hear Bee sound Press 2 and button in the keypad You can hear Bee Ri Rick sound for deletion of remote control 4 Door Opening by Mechanical Key Emergency Insert the key...

Page 7: ...x 20 cards 30 cards Option Frequency AM 433 92MHz Remote Control Reg Capacity 5 Registration Unlock from Inside Voice Message Open Lock Retry Low Battery Warning Display LED Open Close LED Blue LED ON...

Page 8: ...VICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDERSIRED OPERATION CAUTION 1 Changes or modifications not expressly approved by the party responsible for compliance...

Page 9: ...Product View...

Reviews: