33
C o n f i g u r i n g
t h e L a p t i m e r
Setup mode
setting will ignore the warning below a certain
value. This is typically used for engine water
temperature warning.
Blink type:
The blink types are “constant”,
“slow” and “fast”. Fast is typically used by the
shift light, so if that is enabled, try to avoid it
for the warnings.
Example on a more complex warning LED
setup. Here all the settings are used.
In the example above, all the settings are used
for the temperature 1 channel. Here we can
see that this channel is used for the cylinder
temperature. Programmening the warning like
this will give the following warning.
The LED will blink slowly when the tempera-
ture is between 45 and 70 °C and then again
if the temperature is above 85 °C.
Please notice that the same channel can
be used for more warning LEDs.
LCD CONTRAST
Here you can set the screen contrast - that is
the contrast between the screen and the text /
numbers on the screen.
The contrast can be set to a value between
-15 and +15. You will see the contrast change
when adjusting the value.
LED BRIGHTNESS
The LEDs’ brightness can be adjusted from 0%
to 100%.
The LEDs are very powerfull and running them
at high brightness can be dangerous for your
eyes. Always keep them at the lowest bright-
ness level, but still visible at full sunlight. Do
never look directly into them!
SCREENSAVER TIME
When UniGo is not used for a certain time it
will enter in the screensaver mode. This time
can be set from 1 minute to 30 minutes in
steps of 1 minute.
AUTO POWER OFF TIME
When no buttons are pressed and the Laptimer
is not detectning any signals from RPM, speed
and the trigger it will automatically power
off to save the battery. This time can be set
between “allways on” and 30 minutes in steps
of 30 seconds. If set to “always on” it will
never turn off.
TEMPERATURE
UniGo might be used with temperature
displayed in either Celsius or Fahrenheit. With
this setting you can chose between the two.
UNIT
When using UniGo in different countries, it
might be neccessary to change the different
units between Metric and Imperial. Metric
will set speed to kmh, length to meters, sizes
to mm. Imperial set speed to mph, length to
yards and sizes to inches.
LAST LAP DATA
When the start/finish line is passed, the Lap-
timer can show different information on the
last lap. The different settings are “Off”, “Max.
values”, “Delta time”, and “Both”. Here is a
short explanation on what the settings does.
Off:
No special data values are shown when
passing the start/finish line. Everything work-
ing like normal.
Max. values:
The maximum values from the
previous lap are shown when passing the start/
finish line. Please notice that not all channels
have maximum values. An example is the gear
Summary of Contents for UniGo 5005
Page 1: ...UniGo 3005 5005 Laptimer User Guide...
Page 6: ...VI This page was intentionally left blank...
Page 10: ...10 I n t r o d u c t i o n Examples...
Page 18: ...18 I n s t a l l i n g t h e L a p t i m e r Installation...
Page 24: ...24 Q u i c k G u i d e Quick guide...
Page 55: ...55 I n d e x...