11
10
22.03.2022
EN
3.3. DEVICE USE
TURNING THE DEVICE ON:
1.
Connect the device to the power supply. The
operation LED on the control panel will light.
2.
Turning the air purification function on:
•
Press the the air purification function button. The
purification LED will turn on and the device will
start operating.
•
Press the purification function button again to
deactivate.
3.
Switching the dehumidification function on:
•
Press the dehumidification function button when
the device is switched on. The dehumidification
function LED will light up. The device starts
dehumidifying while purifying the air.
•
Press the dehumidification function button again
to deactivate (the LED turns off). The purification
process will continue.
4.
Selecting the operating mode:
•
Press the operation mode button while the air
purification function is on to set the desired
operating power of the device.
•
You can set the quality of the air purification
at low or high. Depending on the setting, a
corresponding LED will light up.
5.
To turn the device off, disconnect it from the
power supply.
CAUTION! Empty the water tank after each use
and let it dry! Leaving water in the tank may cause
bacterial growth.
FILTER INSTALLATION
CAUTION!
1.
Before replacing the filter, turn the device off and
unplug the power cord.
2.
Make sure that the filter is correctly inserted
(check if the filter holder is on the outside, i.e. it is
visible after installation).
3.
Use only filters dedicated to a given device!
4.
When the device detects that the filter is spent,
the air purification lamp turns orange and blinks.
5.
Regularly remove the dust from the filter. Do not
soak the filter in water or any other liquid.
3.2. PREPARING FOR USE
APPLIANCE LOCATION
The temperature of environment must not be higher than
40°C and the relative humidity should be less than 85%.
Ensure good ventilation in the room in which the device
is being used. There should be at least 30 cm distance
between each side of the device and the wall or other
objects. There must be a minimum of 50 cm free space
above the device. Keep the product away from hot surfaces.
The device should always be used when positioned on an
even, stable, clean, fireproof and dry surface, and be out
of the reach of children and persons with limited mental
and sensory functions. Position the device such that you
always have access to the power plug. The power cord
connected to the appliance must be properly grounded
and correspond to the technical details on the product
label.
Turn the device off and unplug the power cord.
1.
Open the filter cover and remove the spent filter.
2.
Remove the protective foil from a new filter.
3.
Install a clean filter.
4.
Close the filter cover as shown on the picture.
* After replacing the filter, turn the device on, then
hold the air purification switch for 7 seconds to
reset the flashing LED.
1
2
3
4
1
2
WATER TANK:
1.
The water tank has a capacity of 600 ml. The
device collects up to 300 ml per day at 30°C and
80 % humidity.
2.
A dehumidification process will automatically stop
when the water tank is full. The device will inform
the user about it with a light indicator which will
turn red. The device will inform the user about it
with a red LED blinking on the control panel.
3.
Turn the device off when the water tank is full.
4.
Pull out the water tank and then pour the water
out of the tank by pulling the tank lid upwards (as
shown on the picture). CAUTION! Do not tilt the
device when the tank is full.
5. Put the water tank back into the device and
restart the device so that it can continue working.
CAUTION!
The tank float must not be moved or damaged! Breakage
of the float may result in the failure of the device!
The operating temperature of the device is 5
°
C – 50
°
C.
The device will stop working with the temperature
below 5
°
C.
DEFROSTING FUNCTION:
The defrosting function will start when the temperature
drops below 13
°
C. The device will pause for 30 seconds
and then run for 2 hours. During this time, the fan will
run continuously to defrost the device.
3.4. CLEANING AND MAINTENANCE
a)
Always unplug the device before cleaning it.
b) Use only non-corrosive cleaners to clean the
surface.
c)
After cleaning the device, all parts should be dried
completely before using it again.
d) Store the unit in a dry, cool place, free from
moisture and direct exposure to sunlight.
e) Do not spray the device with a water jet or
submerge it in water.
f)
The device must be regularly inspected to check
its technical efficiency and spot any damage.
g)
Use a soft, damp cloth for cleaning.
h) Do not use sharp and/or metal objects for
cleaning (e.g. a wire brush or a metal spatula)
because they may damage the surface material of
the appliance.
i)
Do not clean the device with an acidic substance,
agents of medical purposes, thinners, fuel, oils
or other chemical substances because it may
damage the device.
j)
Clean the water tank regularly.
k)
Do not clean the filter with a vacuum cleaner or
directly under water!
l)
It is recommended to regularly expose the filter to
the sun to decontaminate it.
m)
If the device is not used for a long time, make sure
that the water tank is empty and that the device is
dry.
n)
When not in use, store the device covered, e.g. in
a bag or cardboard box.
EN
DISPOSING OF USED DEVICES
Do not dispose of this device in municipal waste systems.
Hand it over to an electric and electrical device recycling
and collection point. Check the symbol on the product,
instruction manual and packaging. The plastics used
to construct the device can be recycled in accordance
with their markings. By choosing to recycle you are
making a significant contribution to the protection of
our environment.
Contact local authorities for information on your local
recycling facility.
Problem
Possible reason
Solution
The device is
not working
The plug is not
connected
Connect the plug
to the power
supply
The water tank is
overfull
Empty the water
tank
Low device
efficiency (low
water level in
the tank)
The filter is spent
Check if the filter
is spent. Replace
if neccessary.
The filter cover is
open
Close the filter
cover
The air inlet/
outlet is blocked
Unblock the air
inlet/outlet
Other similar
device is working
Turn off the other
device
Room
temperature is
too low
Dehumidification
efficiency is lower
in rooms with low
temperature and
humidity
Disturbing
sound
The air outlet is
blocked
Unblock the air
outlet
The device is
tilted
Set the device
in an upright
position
Leakage
The device is
tilted
Set the device
in an upright
position
The device
is moved/
transported with
a full water tank
Empty the water
tank
TROUBLESHOOTING