INSTALLATION AND CONNECTION
19
INSTALLAT
ION AND CONNECTION
Chapter
2
Result, Wave Result, Complete, Load OK, and DPM OK outputs are turned OFF. By turning the
signal from ON to OFF, a “Wait Lv.” State is brought about, or the measurement is started
according to the Measurement Start Condition.
- Stop
It should normally be wired. Use it for stopping
measurement. By turning the signal from OFF to ON
during measurement, the measurement is stopped.
- Hold
It should be wired according to application. Use
only for using the section control function by
External Input. It is not used if the hold function is
not used or Change of Section is made by Setting.
By turning the signal from OFF to ON, the hold
section is changed.
- Reset
It should normally be wired. Use it for releasing
some errors, etc., in emergencies. Irrespective of
the measurement status, by turning the signal from
OFF to ON, the Hold Result, Wave Result, Load
OK, and DPM OK outputs are turned OFF, and a
“Wait St.” state is brought about. If the Reset
signal is turned from OFF to ON during
measurement, the measurement is forcedly
stopped and the measurement data is annulled. For
keeping the data, check the data after completion
of the measurement, and then turn the Reset signal
from OFF to ON.
- Prohibit Touch Panel
It should be wired according to application. Use it for controlling so as to prevent touch panel
operations. As long as the signal is ON, no operation can be performed with the touch panel.
- Backlight On
It should be wired according to application. Use it for controlling the backlight externally. By
turning the signal from OFF to ON, the backlight lights up. As long as the signal is ON, the
backlight stays ON.
- Work
It should be wired according to application. Use it for using two or more work Nos. It is not
used if only work No. 0 is used. Specify work No(s). to be used before measurement.
- COM (Input)
It should always be wired if input signals are used. It is a common terminal to input signals.
Input COMs are internally connected.
Stop input
OFF
ON
Keep ON for
1.5ms or more.
Hold input
OFF
ON
Keep ON for
1.5ms or more.
Keep OFF for
1.5ms or more.
Reset input
All outputs
OFF
ON
Approx. 10ms
1.5ms
Measurement Measurement
in operation
stopped
but Run
OFF
ON
Keep ON for
1.5ms or more.
Summary of Contents for DeviceNet F381A
Page 1: ...15APR2013REV 3 10 DYNAMIC FORCE PROCESSOR F381A OPERATION MANUAL ...
Page 9: ...Contents VIII Contents VIII M E M O ...
Page 34: ...25 2 INSTALLATION AND CONNECTION 25 INSTALLATION AND CONNECTION Chapter 2 M E M O ...
Page 147: ...138 8 SPECIFICATIONS 138 SPECIFICATIONS Chapter 8 8 2 Outside dimensions Unit mm ...
Page 164: ......