13.SPECIFICATIONS
114
Setting item
・
Upper limit / Lower limit /Near zero / SP1/ SP2 / FF CPS. /
Over / Under / Final / Tare
・
Comparison inhibit time/Compare time/
Complete output time/Auto jog timer /
Auto zero times / Judging times /FF CPS. regulation /
Weighing function 1 (Weighing mode, Over/Under comparison,
Upper/Lower limit comparison, Near zero comparison) /
Weighing function 2 (Over/Under comparison mode, Upper/
Lower limit comparison mode, Complete Signal Output mode,
Sign convention for discharge control) / Weighing function 3 (FF
CPS. coefficient, FF CPS.,
Average count of FF CPS., Digital tare subtraction)/
Output selection (Mode selection, Auto jog, At start NZ
confirmation, At start weight value confirmation)/
Motion detection (period, range) /
Zero tracking ( period) / Zero tracking (range) /
Filter (Analog filter, Digital filter) /
Stable mode (Digital filter 2, Motion detection mode ) / Function
selection (Decimal place, 1/4 scale division) / Balance weight /
Capacity / Minimum scale division /
Net Over / Gross Over / DZ regulation /
Gravitational acceleration (Area number) /
Gravitational acceleration (Acceleration)
・
Zero calibration / Span calibration / Tare subtraction /
Tare subtraction reset / Digital Zero / Digital Zero reset
13-4. General Specifications
Power consumption
350
Ω
load cell:
Approx. 300 mA (single load cell)
- Approx. 700 mA (four cells in parallel)
Environment
Temperature: Operational
0
℃
- +55
℃
(accuracy compensation applicable:
0
℃
- +40
℃
)
Storage: -20
℃
- +75
℃
Humidity
:
< 90%RH (non-condensing)
Dimensions 31
(W)
×
90 (H)
×
65 (D) mm (protrusions excluded)
Weight Approx.
150g