10.Multi-Hold Mode
48
10-3. Hold Functions
Points are taken out of waveforms to make a High/Low Limit Comparison by the hold
functions, including Sample Hold, Peak Hold, Valley Hold, Peak-to-peak Hold, Relative
Maximum / Relative Minimum Value Hold, Inflection Point Hold, etc.
Here, detailed operation of each hold is explained.
Switching operation channels during sampling will result in the
following operation.
1. Data of the Judgment output signal (LO1,OK1,HI1) will be
accumulated and output by (LO2,OK2,HI2).
2. The judgment operation is internally reset once, but it is not
necessary to cross over the Hold Start Level again for in Inflection
Point Hold, etc.
・
Ts is a sampling interval [msec].
(Ts=1.0 at 1kHz, and Ts=5.0 at 200Hz for example.)
・
The High/low Limit Judgment output is determined within
0.8msec after the COMPLETE signal is determined.