10.Multi-Hold Mode
50
10-3-2. Peak Hold
The maximum value (peak value) in the positive direction is held.
t1: Delay time between the instant when the T/H signal is input and the instant when the
indicated value is held.
Ts+0.8msec (max.)
t2: Delay time between the instant when the T/H signal is cancelled and the instant when
the indicated value returns to tracking.
Ts+0.8msec (max.)
t2
t
+
T/H
COMPLETE
t1
t2
t1
Note: During the indeterminate period, the Judgment output
varies with variations in the input waveform. However, the
COMPLETE output is kept on during the indeterminate
period. Read the result of judgment when the indicated
value becomes stable (immediately before the rising
edge of T/H).
OFF
ON
OFF
ON
OFF
ON
Sensor input value
Indicated value
Detection/hold period
Detection/hold
period
Indeterminate
period (Note
High/Low
Limit
Output
Judgment