2
3
3) Process of Manual Dry Course
A. Power Button On
➔
“_ _ _” is displayed at 18:88 LED.
➔
“Check Filter” of Custom LED goes on and off before you press Start Button.
➔
“High” of initial Beeper goes on and the previous Beeper value is displayed when you switch on the
power.
B. Operation Selection
➔
Select operation with Course Switch/Button.
➔
“Check Filter” of Custom LED goes on and off before you press Start Button. Once the unit starts
operating, “Check Filter” goes off.
➔
Buttons operate as per 2-1.
➔
The selected Course/Dry Level/Temp Control/Time Dry/Beeper goes on and Custom LED displays
Dry/Cooling.
➔
Option LED may go on and off according to your selection.
C. Operation Process
➔
Once operation starts, LED of Custom LED goes off.
➔
Humidity data are not produced and Heater is controlled by the temperature set by Temp Control.
➔
Time is not changed but drying/cooling continues during the time set initially.
4) Process of Time Dry Course
A. Selection of Time Dry
➔
Course Selection foes off.
➔
Dry Level can not be selected (Default: “High”) but only Temp Control.
➔
Buttons operate as per 2-1 (Same as Manual Dry).
B. Operation Process
➔
The process is the same as Manual Dry.
➔
“Check Filter” of Custom LED goes off if you press Start Button.
합본 svc manual 2008.5.6 6:21 PM 페이지25
Summary of Contents for KUD-WG33S
Page 1: ...JUL 2008 Service Manual Model KUD WG33S Gas Dryer ...
Page 8: ...1 DRYER CBINET ASS Y PartsListbyAss y 7 ...
Page 35: ...33 2 DIAGRAMA SECADORA DE GAS ...
Page 58: ...57 BLOCK DE TERMINALES 1 Remove cover terminal 2 Remove 3 screws sólo secadora eléctrica ...
Page 63: ...4 Switch de Puerta Presione los seguros y empuje hacia el frente ...