2
4
2-3. Operación del Sensor
1) Operation of Heater - Electric Type
➔
On/Off goes on according to temperatures set or measured by the sensor. Regardless of the control by
the microcomputer, however, the heater may go off if a temperature reaches Thermostat Off
Temperature as per outlet conditions.
➔
As regards temperature setting, refer to 2-4 (button operation and temp control).
➔
If you stop the unit temporarily, the machine stops operating until it resumes the function.
➔
If Sensor Course is selected and Temp Control is set to Low or Ultra Low, only the outer heater
operates. Two heaters function if other temperatures are selected.
➔
If Manual Course is selected and Temp Control is set to Low or Ultra Low, only the outer heater
operates. Two heaters function if other temperatures are selected.
➔
If Time Dry Course is selected and Temp Control is set to Ultra Low, only the outer heater operates.
Two heaters function if the temperature is set to Low.
➔
The heater goes off if Cooling or Wrinkle Care is selected.
➔
The heater goes off if Air-Dry of Manual Course is selected, for Temp Control is not available.
2)
Operación de válvula de
Gas
➔
La válvula de gas enciende y apaga cotinuamente de acuerdo a la temp. medida por los
sensores. Sin embargo el termostato
de operación puede apagar el quemador, al alcanzar una
temperatura muy elevada. Independientemente de la temperatura que registra la PCB
.
➔
Para valores de temp. vea la tabla
"
Temp Control Sec
c
i
ó
n 2-4.
➔
En pausa la operación se detien, con reinicio el ciclo de encendido comienza de nuevo
.
➔
La
v
á
lv
ula de gas apaga en ciclo enfriamiento y protección contra arrugas
.
➔
E
n
curso secado por aire no se selecciona control de temp. la válvula de
gas
no
opera.
3) Operation of the Motor
➔
The motor continues its function once operation starts.
➔
The motor stops if you stop the unit temporarily.
➔
The motor continues to operate during Cooling.
➔
If Cooling or Wrinkle Care is selected, the motor turns on for 10 seconds and off for 5 minutes and 50
seconds.
4) Door Control
➔
The heater and motor operate only the door is closed.
➔
If the door is opened during the operation, the heater and motor turn off. If you press Start Button while
the door is opened, LED goes on for a second.
➔
The unit operates only after the door is closed.
합본 svc manual 2008.5.6 6:21 PM 페이지26
Summary of Contents for KUD-WG33S
Page 1: ...JUL 2008 Service Manual Model KUD WG33S Gas Dryer ...
Page 8: ...1 DRYER CBINET ASS Y PartsListbyAss y 7 ...
Page 35: ...33 2 DIAGRAMA SECADORA DE GAS ...
Page 58: ...57 BLOCK DE TERMINALES 1 Remove cover terminal 2 Remove 3 screws sólo secadora eléctrica ...
Page 63: ...4 Switch de Puerta Presione los seguros y empuje hacia el frente ...