43
Thermistor
Ventilador
1. Function
• The fan senses the temperature of exhaust air.
• The higher the temperature is, the smaller the resistance is.
2. Especificación
•
C
aracter
í
stic
as temperatura-resistencia del Thermistor
.
a 90°C : R = 4.43 k
Ω
a 40°C : R = 26.07 k
Ω
• Type name : CWT-DWE-1C18-A
3. Checking method of mal-function
• If the resistance between terminals is within the adequate range, the fan is in
normal operation.
• You can test the resistance of the thermistor as follows.
- Put the metal rod into cold water (10~20°C): 40 within 30 seconds
- Put the metal rod into boiling water (95~100°C): 4 within 30 seconds
• If ‘H2’ error is displayed when you press the power and start button, the thermistor is not connected so
replace it.
4. Procedure of replacement
1
Plate Top remove
2
Panel F Ass'y remove
3
Cabinet Front Ass'y remove
4
Frame Upper remove
5
Drum Ass'y remove
6
Check the position of the part.
7
Remove wires and 1 screw to detach the part.
8
Assemble the parts in reverse order.
Thermistor Fan
Part Code : 361AAAAC20