Note:
Check all piping connections in the unit for leaks. Never use an open flame to
check for gas leaks. Use a soap solution. It is not impossible for connections made at
the factory to leak, due to vibration encountered in transportation. Make certain you
have checked them all, and repair any connections that leak.
The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in
excess of ½ psig.
The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig.
WALL CLEARANCES
All units must be installed in accordance to minimum rear and side wall clearance
and clearances extended vertically above cooking top which are stated on the serial
plate. (The serial plate is located below the cooktop.)
ANY OPENINGS IN THE WALL BEHIND THE UNIT AND IN THE FLOOR
UNDER THE UNIT MUST BE SEALED.
Note. Due to potential hazards it is recommended that storage cabinets not be
installed above the cooking surface.
IN THE EVENT OVERHEAD CABINETS ARE INSTALLED, THE
MAXIMUM DEPTH OF CABINETS INSTALLED ABOVE COOKING TOPS
SHOULD BE 13”.