GAS RANGE CONVERSION (continued)
Convertible Pressure Regulator
The range is shipped to operate on LPG. NG orifices and a special screwdriver for
adjusting the minimum flame are shipped with the unit in a separate envelope with the
manual. The inlet pressure of the gas supply shall be in accordance with the nominal
inlet pressure of the regulator used on the range or 1/2 psig maximum.
The range should be tested by pressurizing the regulator with an inlet pressure at least
1 inch water column above the manufacturer’s specified manifold pressure shown on
the serial plate.
1.
CAUTION:
Before proceeding with the
conversion, shut off the gas supply to
the appliance prior to disconnecting the
electrical power (if applicable).
2. Locate convertible regulator at the back
of the range, left side facing appliance.
Remove cap and pop out the pin that’s
attached
3. On the side you will see the pin position for
use with LPG
4. Unscrew pin and flip it to the NG position – long end outwards, spring on inside.
5. Below is an example of additional positions depending on regulator type installed.
6. Replace the cap back on the regulator
7. Next you will remove the grates, burners and burner caps from the range to access
the orifices.
8. You will need a 7 mm wrench to remove the orifices.
Each orifice can be accessed easily - the larger
burner orifice is located on the burner wall.
9. Remove all LPG orifices: place in the bag and store
in a safe place.
BURNER ORIFICE
ORIFICE LOCATION
LPG