16
U N I Q U E U G P 3 0 G
.
Convertible Pressure Regulator
The range is shipped to operate on LPG. NG orifices and a special screwdriver for
adjusting the minimum flame are shipped with the unit in a separate envelope with
the manual. The inlet pressure of the gas supply shall be in accordance with the
nominal inlet pressure of the regulator used on the range or 1/2 psig maximum.
The range should be tested by pressurizing the regulator with an inlet pressure at
least 1 inch water column above the manufacturer's specified manifold pressure
shown on the serial plate.
1.
CAUTION:
Before proceeding with the conversion, shut off the gas
supply to the appliance prior to disconnecting the electrical power
2. Locate convertible regulator at the back of the range, left side facing
appliance. Remove cap and pop out the pin that’s attached
3. On the side you will see the
pin positon for use with LPG
5.Unscrew pin and flip it to the
NG position – long end
outwards, spring on inside.
6.Below is an example of additional positions depending on regulator type
installed.
7.Replace the cap back on the regulator
8.Next you will remove the grates, burners and burner caps from the range
to access the orifices.
9.You will need a 7mm wrench to remove the orifices. Each orifice can be
accessed easily - the larger burner orifice is located on the burner wall.
9,000
3,000
9,000
10,000
13,000
44,000
9,000
3,000
9,000
10,000
13,000
44,000
Manifold Pressure:
Natural Gas: 4” WC / LP/Propane: 10” WC
Electrical Rating:
1.5V DC. 1.0 A