18
18.
Locate the burner tube and locate the retaining screw at the front of the tube.
Once this screw has been removed, lift up the burner and pull away slightly to the
right to expose the oven orifice.
19.
With a 7mm wrench or pliers remove the orifice and replace with NG orifice.
20.
Replace the burner tube, then start up the oven to check oven flame, making sure
21.
22.
it’s tight and blue. Adjust the air shutter at the back of the burner tube to achieve
this. Once you have the bottom pan and oven door closed, and with the broiler
drawer pulled down, you will be able to see how the flame should look by
viewing the flame through the broiler door area.
Orifice
Wrench
U N I Q U E U G P 3 0 G
In the pilot assembly shown below, the LPG ori
fi
ce is 0.14 mm. When doing
the conversion from Propane to Natural
gas make sure the pilot or
ifi
ce is
changed to the NG or
ifi
ce sized at 0.2 mm. If you leave the LPG ori
fi
ce
0.14mm in place, the pilot
fl
ame will may be too small to keep the pilot lit
.
Pilot Orifice
Oven Orifice
Check for leaks using a leak detector or soapy water with recommended ratio
of 75% water, 25% dish washing soap.
Once you have completed the conversion, check the operations of ignition
making sure each of the 4 burners, pilot flame and oven burner flame are
functioning correctly. Pleases refer to pages 19 through 22
Oven
Pilot
Igniter
Pilot Orifice
Thermocouple