escape from the gas line and flow up to burner.
Length of time will vary depending on
distance of the fridge to propane tank.
Continue pushing the igniter button while
holding in the gas button until the needle in the flame indicator
D
moves into the green
area (to the right).
4.
When the needle starts to move into the green area, this means flame is now lit. Stop
sparking and continue to hold gas button
E
down for an additional 10 seconds. Release
gas button, fridge should now stay lit and needle remains in the green area.
5.
Once all the above has been done and you are ready to re-start your fridge for use, leave
the thermostat button at
“4”.
Setting the thermostat to
"4"
will allow the fridge to get to
optimum cooling temperature. It may be necessary to adjust the temperature control on
the thermostat knob to suit your needs.
6.
The quantity of food in the refrigerator, the frequency with which the refrigerator doors
are opened and the room temperature will all affect refrigerator temperatures.
“Shut Down” Procedure
1. Turn knob C to Gas “Off” position – to the right.
Note: If using CO-Monitor , the monitor must be hooked up and be reset with
the battery installed for the flame to stay on – Refer to Chapter 6
CONTROLS –
See Fig 5. for description of controls
Figure #5