7
OPERATION
STARTING THE FREEZER
After the freezer has been properly connected to a power source, the compressor will automatical-
ly turn on and the cabinet will begin cooling. Allow the cabinet to cool for at least 4 hours prior to
adding foodstuff.
TEMPERATURE CONTROL
The temperature within the freezer compartments is controlled by the thermostat situated on the
top of the freezer area. When you first start the freezer we suggest that you turn the thermostat to
a maximum setting until desired freezer temperatures are achieved. The correct internal tempera-
ture setting can be found by measuring the temperature of the central or middle portion in the
appliance.
• The larger numbers indicate the coldest setting.
• The smaller numbers indicate the warmest setting.
When you first start the freezer we suggest that you turn the thermostat to a maximum setting (4)
until desired refrigeration temperatures are achieved. The correct internal temperature setting can
be found by measuring the temperature of the central or middle portion in the appliance. Internal
temperature of the appliance can vary based on ambient temperature, the quantity of items stored
and how frequently the door is opened.
Note:
The freezer will run a few degrees colder at high
elevations.
ADJUSTMENTS
As the ambient temperature changes with the season, it may be necessary to adjust the thermo-
stat to achieve the proper internal temperature. If the room/ambient temperature approaches the
appliance’s internal operating temperature, the appliance will not function as it should. The appli-
ance will tend to run colder during these conditions and it may be necessary to turn the thermo-
stat to a warmer setting (lower number). If the room/ambient temperature exceeds 100˚F (38˚C),
the appliance will not function as it should. The appliance will tend to run warmer and it may be
necessary to turn the thermostat to a colder setting (towards the maximum setting).
LEVELING INSTRUCTIONS
There are adjustable legs on the bottom of the front of the appliance that can be turned up or
down to ensure that the appliance is level.
1. Turn the leveling leg counter-clockwise as far as it will go, until the top of the foot is touching the
bottom of the cabinet.
2. Slowly turn the leveling leg clockwise until the appliance is level.
OPTIMAL OPERATING TEMPERATURE
THERMOSTAT
SETTING
FREEZER TEMPERATURE
Optimal
Setting = 1.6
-10˚C to -15˚C
14˚F to 5˚F
Setting = 4
-25˚C / 5˚F
NOTE:
Setting 1 being warmest and 4 coldest
NOTE:
Mechnical tempera-
ture controller has a + or -
, 0.5 range. The freezer will
run a few degrees colder
at high elevations.