Gas Connection
Hook-up to the gas supply line: 3/8” SAE (UNF 5/8” - 18) male flare connection. A backup
wrench must be used when tightening gas supply fitting. All completed connections should be
checked for leaks with a non-corrosive leak detector and/or soap and water for a bubble check..
W
ARNING
–
D
O NOT USE FLAME TO CHECK FOR GAS LEAKS
The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not
more than 12” water column and no less than 11” water column. (max setting)
Make sure the refrigerator and any other high BTU appliances on your line are turned on when
checking the gas pressure. The appliance and its individual shut-off valve must be disconnected
from the gas supply piping system during any pressure testing of that system at pressures in
excess of ½” psig.
In case detailed instructions on the installation and connection of the gas supply are required,
contact your dealer or distributor.
Leveling
Ensure the fridge is level by using a 2ft level. This is accomplished by adjusting the feet at
the front, underneath the fridge.