5. Using an adjustable wrench replace the cap back on the regulator, do
NOT
over
tighten cap.
6. Remove the grates, burners and burner caps from the range to
access the orifices.
7. Use a 7mm wrench to remove the orifices. Each orifice can be located in the
center of the burner base - see fig 2
Burner Orifice
8. Remove all NG orifices, place in the bag and store in a safe place.
9. Take the LPG orifices provided and install them as shown below, do NOT over-
tighten
See below for rating of orifice for each model
Front RIght Rear Right Front Left Rear Left Oven
Broil
LPG 0.53 mm
1.00 mm
0.9 mm
0.68
0.82 mm 0.8 mm
10. Once all the orifices are installed, replace all burners and burner caps.
NOTE:
Top flame burner height adjustment instructions are located on page 27
GAS RANGE CONVERSION
LPG
NG
fig 2
Summary of Contents for UGP-20V PC1 S/S
Page 21: ...21 WALL CLEARANCES continued ...
Page 46: ...UGP 20V PC1 S S WIRING DIAGRAM 46 ...