U N I Q U E U G P - 2 2
15
TROUBLESHOOTING INSTRUCTIONS &
SUGGESTED SPARE PARTS TO KEEP ON HAND
REFRIGERATOR DOES NOT COOL, CHECK LIKELY CAUSES:
1.
Burner orifice clogged. Clean. See section Maintenance & Service, C
HAPTER
4,
Item #2. Periodic Maintenance, Items 1-9.
2.
Check to ensure refrigerator is level – (left to right and front to back).
3.
Restriction on air flow across cooling unit.
4.
Heavy frost build up on evaporator fins. Defrost.
5.
Flue baffle not inserted properly in flue tube.
6.
Improperly set thermostat. See paragraph on thermostat. In hot weather or
heavy use the setting should be closer to “Max” than usual.
7.
Burner dirty. Clean. See Section M
AINTENANCE
&
S
ERVICE
,
C
HAPTER
4,
P
ERIODIC
M
AINTENANCE
8.
LP gas pressure low at burner. Regulator pressure must not drop below 11
inches W.C (water column). C
HAPTER
2,
G
AS
C
ONNECTION
9.
Burner not located properly under the flue tube. Relocate, flame must be
directly into flue
10.
Burner damaged. Replace.
11.
Odours and fumes
•
Dislocated burner
•
Damaged burner
•
Dirty orifice
•
Dirty flue tube – C
HAPTER
4.
Chapter
5