26
ADJUSTING THE TOP BURNER AND OVEN FLAME
Keep appliance area clear and free from combustible materials,
gasoline, and other fl ammable vapors and liquids. Do not obstruct the
fl ow of air that is necessary for combustion and ventilation.
Top Burner Valves
The top burners have orifi ces that are dedicated to the type of fuel to be used.
These orifi ces are not adjustable. They must be changed completely to convert
from one gas to the other. DO NOT DISCARD THE UNUSED ORIFICES. They
should be saved in order to convert the range back to its original fuel.
When converting the gas valves, the minimum fl ame adjustment screw must be
adjusted.
Please see the supplied screwdriver in the conversion kit along with the orifi ces.
The proper fl ame size is approximately ¼” obtained. – see adjustment procedure
below.
The properly adjusted maximum fl ame is approximately ¾” high and has three
distinct cones; the kindling point, the dark blue center cone, and the outer mantel.
ADJUSTING THE TOP BURNER FLAME
1. Ensure the range has gas supply and power
2. Light the burner
3. Set the top burner valve to the minimum position
4. Remove the knob by pulling straight out
5. Turn the valve fully counter clockwise.
Then proceed to adjust the adjustment screw
counter clockwise for a smaller fl ame and
clockwise for a larger fl ame. Adjustment:
Minimum fl ame should be approx. ¼” tall
Orifi ce Location Adjustment location is inside the valve stem
6. Temporarily replace the lid, burners, burner caps and grates and recheck the
fl ame. Once complete, reassemble the control panel and the lid.
7. Replace the knob
8. Repeat for each of the other burners
26
FLAME HEIGHT ADJUSTMENT
Adjustment location is inside the valve stem
Summary of Contents for UGP-24CR W