Gas Range Conversion and Adjustment Guide
To Convert and/or Adjust to Natural Gas
The range is set for use with Liquefied Petroleum (LP). The factory setting is
indicated on the serial plate. When set for LP Gas operation, the pressure regulator
will regulate the gas to 10 inches water column pressure. When set for Natural Gas
operation, the pressure regulator will regulate the pressure to 4 inches water column.
LPG to NG Conversion
Convertible Pressure Regulator
The range is shipped to operate on LPG. NG orifices and a special screwdriver for
adjusting the minimum flame are shipped with the unit in a separate envelope with
the manual. The inlet pressure of the gas supply shall be in accordance with the
nominal inlet pressure of the regulator used on the range or 1/2 psig maximum. The
range should be tested by pressurizing the regulator with an inlet pressure at least 1
inch water column above the manufacturer's specified manifold pressure shown on
the serial plate.
1.
Shut off gas leading to appliance
2.
Unplug any electrical connections if applicable.
3.
Locate convertible regulator at the back of the range, left side facing
appliance. Remove cap and pop out the pin that’s attached
4.
Below you will see the pin positon for use with LPG
5.
Unscrew pin and flip it to the NG position – long end outwards, spring on inside.
6.
Below is an example of additional positions depending on regulator type installed.