U N I Q U E E L I T E 3 0 E & 3 6 E
15
The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in
excess of ½ psig.
The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig.
Installation
It is the responsibility of the installer to make certain that the range is properly
adjusted at the time of installation. Situations caused by improper adjustments or
improper installation are not covered under the warranty. Any expenses incurred due
to such situations will not be paid by the manufacturer of the appliance.
Connecting gas to range
This range is designed to operate at a pressure of 4” of water column on natural gas
(NG) or 10” of water column on propane gas (LPG).
Make sure you are supplying your range with the type of gas for which it is designed.
This range comes equipped from the factory equipped for use with LPG
(propane).
This range is convertible for use on natural gas (NG) also. (Natural gas
Gas line shut-off valve
To reduce the possibility of gas leaks,
apply Teflon tape or a thread
compound approved for use with LP
or Natural gases to all threaded
connections.
Connect a ½” threaded pipe to the
units regulator located at the back
right of the unit. We suggest using a
½” female to 3/8” male flare adaptor
on the end of the ½” threaded pipe.
Use a flexible appliance connector to
connect your gas supply to the
appliance. A 3 foot length is
recommended for ease of installation
but other lengths are acceptable.
Never use an old connector when
installing a new range.
Check for leaks using a leak detector
or soapy water with a recommended
ratio of 75% water, 25% dish washing
soap
Summary of Contents for UGP-30E OF1
Page 13: ...U N I Q U E E L I T E 3 0 E 3 6 E 9 ...
Page 14: ...U N I Q U E E L I T E 3 0 E 3 6 E 10 UGP 36E Specs ...
Page 16: ...U N I Q U E E L I T E 3 0 E 3 6 E 12 UGP 30E and 36E Cut out Specs ...
Page 43: ...U N I Q U E E L I T E 3 0 E 3 6 E 39 Wiring Diagram UGP30E OF1 ...
Page 44: ...U N I Q U E E L I T E 3 0 E 3 6 E 40 Wiring Diagram UGP36E OF1 ...
Page 45: ...U N I Q U E E L I T E 3 0 E 3 6 E 41 Parts Diagrams UGP 30E OF1 ...
Page 46: ...U N I Q U E E L I T E 3 0 E 3 6 E 42 UGP 36E OF1 with Griddle ...